— 26 —
VIII. Recording of Diagnostics Data
Diagnostics designed to troubleshoot issues with software applications. A log contains
all sent and received NMEA 2000 messages and all data sent and received from
and to the NMEA server #1 port (see IV). The NMEA server #3 can be configured to
send log data in a real time to a web browser or terminal application.
1.
Configure problem application to use port of server #1.
2.
To get the diagnostics log, configure server #3 port to the “Debug” data protocol
(it is TCP network protocol).
3. If the Gateway has the address 10.1.1.1 and server #3 port has a number 1500,
type
http://10.1.1.1:1500
in browser address bar (experienced users can also
use terminal applications to get data from this port).