— 35 —
Incorrect fluid level
readings
1. Fluid level sensor connection issue.
Check if the fluid level sensor is
connected according to the instructions given in Section II. Check the fluid
level sensor and its wires for shorts and failed connectivity.
2. Incorrect Device settings
(wrong connection method, sensor resistance
range or coil resistances are set in the device configuration). Reconfigure the
Device (refer to Sections IV - VI).
3. Fluid level sensor needs calibration.
Perform calibration as
described in Section VI.4.1.
The Device is displayed
in the list of devices on
the chart plotter, but fluid
level data does not appear
on the screen, status LED
flashes GREEN
1. Incompatible equipment.
Make sure that your hardware supports
reception of the «Fluid Level» 127505 PGN. Update the firmware of your
equipment if necessary.
2. Fluid level meter or gauge is not enabled in the chart plotter
settings.
Check the «data pages customization» section of the chart plotter
manual and enable the gauge.
3. Chart plotter does not support selected fluid type
(e.g. GASOLINE).
Try to set another fluid type (e. g. DIESEL; refer to Section VI.2.2).
Table continued