— 24 —
3. Sensor configuration
3.1 YD:CONNECTION <A..D> [NC | RESISTIVE | 1COIL | 2COIL | VOLTAGE | 2COIL_VCC | MDI]
Sets the sensor type and connection type for specified channel (see Section II). With factory settings, all
channels are configured for RESISTIVE type (standalone connection to resistive sensor). The NC type
means “not connected” and mark the channel as unused for the Device. The settings below in this section
are applied depending on selected connection type.
3.2 YD:OHMS_SENSOR <A..D> [range]
Where: [range] can be specified as two numbers in Ohms, where the first number corresponds to an
empty tank and the second to a full tank, or as EUR (equal to 10 180), USA (240 33) or JAP (0 310).
The range specified by numbers is limited by 0..400 or 400..0 intervals, borders can be configured with
0.01 Ohm precision. With factory settings, all channels are configured for USA type of sensors (240 Ohms
when empty, 33 Ohms when full).
This setting is applicable only with RESISTIVE, 1COIL, 2COIL, 2COIL_VCC connection types.
Example 1.
Configure channel A for a sensor with a range of 235 Ohms (when empty) to 10.45 Ohms
(when full):
YD:OHMS_SENSOR A 235 10.45
Example 2.
Configure channel B to a European type of the sensor, two options possible:
YD:OHMS_SENSOR B 10 180
YD:OHMS_SENSOR B EUR
3.3 YD:OHMS_GAUGE <A..D> [<0.00..10000.00> [<0.00..10000.00>]]e]
Содержание YDTA-04N
Страница 1: ...User Manual Tank Adapter YDTA 04 also covers models YDTA 04N Firmware version 1 00 2021...
Страница 6: ...6 I Product Specification Figure 1 Drawing of Tank Adapter YDTA 04N...
Страница 28: ...28 Figure 1 Automatic management of ballast tanks with YDCC 04 and YDTA 04...
Страница 33: ...33 Figure 1 Firmware update with CAN Log Viewer...
Страница 40: ......