— 14 —

Table 1. Applicability of the programming methods

 

 

Number Setting or action

Method

[1]

[2]

[3]

(1)

NMEA 2000 device instance

Yes

Yes

Yes

(2)

NMEA 2000 system instance

Yes

Yes

Yes

(3)

NMEA 2000 data instance

Yes

Yes

Yes

(4)

Inside / outside

Yes

Yes

Yes

(5)

Turn on/off transmission of humidity, air temperature 

and dew point temperature

Yes

Yes

Note 3

(6)

Transmission interval for periodic messages

Note 1

Yes

Yes

(7)

Humidity and temperature offset

No

Yes

Note 3

(8)

Installation description

No

Yes

Yes

(9)

Reset all settings to factory values

Yes

Yes

Note 3

(10)

NMEA 2000 message priority

No

No

Note 2

Note 1:

Only turning on with default transmission interval and off are allowed with this method.

Note 2:

Setting is not stored in non-volatile memory and acts only while Device is powered.

Note 3:

Not allowed with "Command Message" and "Write Fields" of PGN 126208, use method 2.

NMEA 2000 device (1) and system (2) instances should not be modified by a user, these fields are used 

 

by  installers  in  complex  NMEA  2000  networks.  Message  priority  (10)  can  be  dynamically  managed 

 

on the network by devices and is not intended to be managed by a user.

Содержание YDHS-01

Страница 1: ...User Manual Humidity Sensor YDHS 01 also covers models YDHS 01R YDHS 01N Software version 1 02 2018...

Страница 2: ...S01 002 March 15 2018 Web http www yachtd com NMEA 2000 is a registered trademark of the National Marine Electronics Association SeaTalk NG is a registered trademark of Raymarine UK Limited Garmin is...

Страница 3: ...Testing 11 V Device Programming and Settings 13 VI Programming with Installation Description String 17 VII Programming with Datum or Variation 20 VIII LED Signals 25 APPENDIX Troubleshooting 26 APPEND...

Страница 4: ...a NMEA 2000 network and is compatible with a wide range of equipment supporting this protocol Raymarine SeaTalk NG Simrad SimNet and Furuno CAN networks are branded versions of NMEA 2000 and differ on...

Страница 5: ...ost of equipment installation and configuration as well as shipping of the defective Device to the manufacturer 5 Responsibility of the manufacturer in case of any damage as a consequence of the Devic...

Страница 6: ...f NMEA 2000 connectors Models with the suffix R at the end of the model name are equipped with NMEA 2000 connectors compatible with Raymarine SeaTalk NG as in the picture above Models with the suffix...

Страница 7: ...in the rest of range 3 RH Relative Humidity Measurement Operating range 40 120 Measurement resolution 0 01 Typical accuracy in range 5 60 C 0 3 Accuracy in the rest of range maximum 1 Note 1 Normal op...

Страница 8: ...not point a jet of high pressure at the sensor This can damage the membrane or lead to the penetration of water through the membrane The sensor is not light sensitive but long exposure to direct sunli...

Страница 9: ...from metal surfaces or surfaces that can be heated from inside or from other parts of the boat 4 Do not place the sensor where it can be flooded by water gets wet in the rain or sprayed with water In...

Страница 10: ...10 Figure 1 Sensor fixed with supplied pads and plastic clamps A side view B isometric C fixing of clamp...

Страница 11: ...th factory settings will produce two short signals every second This indicates normal operation see chapter VIII If the Device is connected to a network having a chart plotter or any other device tran...

Страница 12: ...the Device shows the data as outside humidity and air temperature and sends a calculated dew point temperature Switch to the chart plotter screen which provides information about the air temperature...

Страница 13: ...and Raymarine chart plotters See chapter VII for details 2 With a special installation description string which can be entered for the Device iin PC software like CAN Log Viewer from our company Acti...

Страница 14: ...ation description No Yes Yes 9 Reset all settings to factory values Yes Yes Note 3 10 NMEA 2000 message priority No No Note 2 Note 1 Only turning on with default transmission interval and off are allo...

Страница 15: ...led In theory this conflict can be solved by assigning different data instances 3 to the Devices or selecting a data source in the chart plotter or instrument display But in practice many of modern ch...

Страница 16: ...ted in method 3 see Appendix C In case of method 1 the user can only turn on and off transmission of messages The Device sensor is calibrated at the factory and wrong readings usually mean that the se...

Страница 17: ...ify the device location or to leave notes or contact information This can be done with professional PC software with a hardware connector to NMEA 2000 network and it may be supported by some models of...

Страница 18: ...ce and click Properties button You can download this program runs on Microsoft Windows Mac OS X and Linux at http www yachtd com downloads Yacht Devices NMEA 2000 Wi Fi Gateway or Yacht Devices NMEA 2...

Страница 19: ...30313 130316 in milliseconds Values from 50 to 3600000 1 hour are allowed value 0 turns transmission of specified PGN off See also Table 2 of previous chapter YD DATATYPE string YD DATATYPE NONE YD DA...

Страница 20: ...the Device with this method you must connect it to a network with a chart plotter This method of programming is tricky but is compatible with virtually all NMEA 2000 chart plotters Figure 1 Setting th...

Страница 21: ...date the plotter firmware STEP 1 Putting the Device into standby mode The Device enters standby mode if when it is switched on the chart datum is set on the plotter to Ireland 1965 or if the magnetic...

Страница 22: ...returns to normal operation mode The settings are not saved into non volatile memory and if the Device settings were changed at the time of programming they will be kept only until the Device power i...

Страница 23: ...15 Factory setting is 0 Campo Inchauspe Argentina 23 E Increase NMEA 2000 device instance value 0 255 reset to 0 after 255 Factory setting is 0 To decrease value reset all settings to factory values...

Страница 24: ...on the transmission of PGN 130311 setting value of 0001 binary Note 2 1st bit least significant corresponds to humidity 2nd bit to air temperature and 3rd to dew point temperature Factory setting has...

Страница 25: ...0 5 second interval Device cannot claim NMEA 2000 address Possible under special factory tests only Signals with length of 1 second or more from time to time Cable is located near refrigerators alter...

Страница 26: ...and the plotter 1 Loose connection in the data circuit Treat the Device connector with a spray for cleaning electrical contacts Plug the Device into another connector 2 There are problems in the NMEA...

Страница 27: ...27 APPENDIX B Device Connectors Figure 1 NMEA 2000 connectors of the YDHS 01R left and YDHS 01N right models...

Страница 28: ...6993 Heartbeat Yes 60 PGN 126996 Product Information Yes PGN 126998 Configuration Information Yes PGN 127258 Magnetic Variation Yes 2 PGN 129044 Datum Yes 2 PGN 130311 Environmental Parameters Yes 0 5...

Страница 29: ...____________________________________ ___________________________________________________________________ ___________________________________________________________________ ___________________________...

Страница 30: ...___________________________________________________________________ ___________________________________________________________________ ________________________________________________________________...

Страница 31: ......

Страница 32: ......

Отзывы: