background image

14

Apply the included skin-care product to the center of the 
electrode head and then apply the electrode head to the skin 
and move it around.

Divide the facial treatment in six areas (pages 15-16).
Apply one pearl-sized drop of the included skin-care product for each area.

3

Care for the skin after the 
treatment

After treatment is complete, rub the remaining 
skin-care product into the skin and then use your 
usual basic skin-care products to condition the skin.

4

Included skin-care product

(About one pearl-sized drop)

ATTENTION

See “How to move the device” (pages 15-16) for 
information on how to move the device correctly.

•  Do not apply the included skin-care product with your hand. Doing so may lead the 

skin-care product stick on the device or cause it to slip and fall.

•  If the device does not move smoothly, apply more of the included skin-care product.
•  Use in a position in which the entire surface of the electrode head comes in contact 

with your skin.

•  Be sure to move the device on your skin while using it.
•  If it feels too hot, move it a little more quickly or lower the level.

•  Do not use the device on the Adam’s apple, the eyelids, or 

around the eyes.

Содержание S12

Страница 1: ...n 8 Names and Functions of Components 9 Before Use 11 How to Use 13 After Treatment 18 Additional Information 20 Troubleshooting 20 Frequently Asked Questions 22 Product Specifications 23 After sales...

Страница 2: ...ccessible location Make sure to include this User s Manual if you are transferring ownership of the device to another person Classifications of Precautions Symbols Read these Safety Precautions carefu...

Страница 3: ...ave atopic dermatitis If you have skin problems If you have sensitive skin If you have unhealthy skin blemishes caused by physical irritation If you are experiencing skin irritation or redness due to...

Страница 4: ...inors should use the device only under the supervision of a guardian who has given their consent Failure to comply may cause an accident or an injury Do not use the device on individuals who are unabl...

Страница 5: ...ation or discomfort by EMS on your cheeks or chin If you feel strong discomfort consult a physician If you sense an earthquake or see lightning turn the power off or disconnect the AC adapter while th...

Страница 6: ...roken Do not use the device if it is damaged or malfunctioning Failure to comply may cause your skin to suffer an injury or other problems or lead to the worsening of existing conditions Do not use co...

Страница 7: ...Failure to comply may cause an accident or injury When you have not used the device for a long period of time check to see that it is functioning normally before re starting use Failure to comply may...

Страница 8: ...t fire or failure of the device WARNING The power supply Do not damage modify bundle or otherwise apply undue force to the AC adapter or USB cable Failure to comply may cause the cable to break result...

Страница 9: ...Failure to comply may cause a fire electric shock or a failure of the device Be sure to use in an operating voltage range from 100 to 240 volts Failure to comply may cause the generation of heat a fi...

Страница 10: ...9 Names andFunctions of Components Level lamp MainBody Electrode head Power button Charging terminal USB Type C Front view Rear Level button...

Страница 11: ...sor may reduce the level of warmth Timer The treatment duration on the entire face is about six minutes Device will make one long beep after three minutes as an alert Auto Power Off The device will au...

Страница 12: ...ping sound Notification of error with seven beeps In some cases the device might not charge properly if using a generic cable or AC adapter Using a household power outlet USB cable Charging terminal H...

Страница 13: ...h your skin Wash the inner side of your arm with soap and water then wipe dry with a towel Apply the included skin care products about one pearl sized drop to the center of the electrode head turn the...

Страница 14: ...tment level from the level lamp Level 1 Warms up gradually gentle EMS Level 2 Level 3 Warms up quickly strong EMS For safety reasons the device is set to Level 1 when turned on Level button Level 1 la...

Страница 15: ...in care product About one pearl sized drop ATTENTION See How to move the device pages 15 16 for information on how to move the device correctly Do not apply the included skin care product with your ha...

Страница 16: ...ly the included skin care product Apply the included skin care product Do not add more of the included skin care product Apply the included skin care product Recommended speed for moving the device 4...

Страница 17: ...ownward direction along the nape of the neck Do not add more of the included skin care product In a downward direction along the nape of the neck Apply the included skin care product Automatic Power o...

Страница 18: ...tions of the arrows three times each in order from to as shown below From the tip of the chin to below the ears three times Back and forth below the ears three times From top to bottom along the nape...

Страница 19: ...tton bud or cotton pad WARNING When cleaning the device be sure to turn it off and disconnect the USB cable from the main body Failure to comply may cause an electric shock short circuit or fire Do no...

Страница 20: ...and Inspections If you have not used the device for an extended period inspect it carefully and check that it works properly and safely before using it again If the device is malfunctioning go to Tro...

Страница 21: ...tion The device does not turn on The device shuts off The device only operates for a few minutes even after charging Insert the included USB cable into the main body page 11 Check to make sure the cab...

Страница 22: ...button page 13 This is the Personal Memory Function page 13 operating The Power button light turns red The level does not begin at Level 1 It is displaying the remaining battery level page 10 Raise t...

Страница 23: ...roducts that you already own use the recommended usage amounts as a guide We recommend using gel skin care products If you feel that the amount of skin care product is insufficient add more Can I use...

Страница 24: ...esin and polycarbonate Electrode head Stainless steel Approximately 175 g Approximately W 46 x D 47 x H 173 mm Approximately 9W when charging Recommended environmental temperature 10 to 40 C Battery L...

Страница 25: ...Disposing of the device Follow your local government rules for proper disposal of this product This product uses a lithium ion battery Contacts for overseas customers For countries and regions outside...

Страница 26: ...d cosmetics Please contact your local distributor for detailed information on products and purchases Sales may be discontinued without prior notice Flawless Serum moisture Item No Quantity 80g 200g CS...

Отзывы: