FUNCTION INTRODUCTION
Soldering /desoldering function introduction
(Both soldering and desoldering function can be set in the same way.)
TEMPERATURE SETTING:
(No password set)
1.
Increase temperature: By pressing “▲” key one time, the digital will be increase “1” numeral. If
pressing “▲” key over 2 seconds then the digital numerals will be forwarded counting
continuously till the temperature up to what you desire to set.
2.
Decrease temperature: By pressing“▼” key, the same procedure as above.
PARAMETER SETTING:
1.
Press “SET” key and hold for at least
5 seconds until display shows“— — —” sign then release
the “SET” key. The sign “— — —” starts to flash and reminding the user to input the mode lock
password “010” (fixed). If the user inputs the same number as “010”, the unit will enter the
modes selection procedure, otherwise, the unit will be back from the current mode automatically.
2.
After the unit enters the Modes selection, the LED will display “F-0”and flash. Press “▲”or “▼”
key to select modes. If the user doesn’t press “▲” or “▼” key within 15 seconds or press “SET”
key one time, then the unit will be immediately back from the Parameter Set status.
For example: F-0 → F-1 → F-2 → F-3 →F-4
↑ ↓
← ← ← ← ←
3.
Password Setting:
When the LED displays “F-1” and flashes, press “SET” key one time and the unit enters the
Password Set status. At this moment, the LED displays the pre-set value. Press “▲” or “▼” key
to change password set value. If the user sets “000” that means the unit will be under the status
of no password. If the user sets “100” then means the unit will be under the password status.
Press “SET” key once to finish password setting and the unit will backup mode, the user can
continue set other modes or back from the setting mode.
4.
Temperature Correction Setting:
Press “SET” key once when the LED displays “F-2” and flashes that the unit enters the
Temperature Correction Mode. At this moment, the LED displays preset correction value.
A: Operation of Centigrade temperature correction
(+99℃~-99℃):
Press “▲” or “▼” key to change the temperature correction value. The first digit “— ” means
minus (actual temperature is down), “No display” means plus (actual temperature is up).
B: Operation of Fahrenheit temperature correction value
(+178℉~-178℉):
Press “▲” or “▼” key to change the temperature correction value. The first digit “— ” means
minus (actual temperature is down), “No display” means plus
.
Press
“SET” key once to finish
the temperature correction and the unit automatically backup mode. The user may continue set