Xytronic LF-853D Скачать руководство пользователя страница 3

 
 

 

they do not play with the appliance.   

 

To prevent electrical shock, be sure to take the following precautions:   

 

1. Make sure the unit is grounded. Always connect power to a grounded receptacle.   
2. Do not pressure the AC power cord. Be sure the work area is well ventilated.   
3. Do not bump, hit, pour water/liquids or otherwise subject the heating surface to   

physical shock. This may damage the heater.   

4. To isolate the equipment from the mains before commencing repairs or making any maintenance 

to avoid electric shock. This may result in Death or serious injury.   

5. Do not expose the unit to moisture nor use the unit with wet hands.   
6. Turn the power switch off and remove the AC power cord by pulling the plug (not the cable) when 

the unit will remain unused for a longer period of time.   

7. Do not modify the unit. 
   

           

           

           

           

Warning   

 
Soldering / Desoldering Function Warning 
 

◆ 

Always place the soldering & desoldering irons in its original holder when not being used. 

◆ 

Keep the soldering and desoldering tip and heating element away from the body, clothes and 
flammable material when in operation. 

◆ 

The soldering and desoldering tip and the heating element are still remaining hot after being 
switched off. Ensure that you do not touch the tips and the heating elements. 

◆ 

For your health, do not inhale solder fumes. 

◆ 

You must not undertake work on live parts. Only the technician is permitted to undertake repairs. 
Use the original replacement part only.   
 

Hot Air Function Warning 

 

To last the life of the heating element, not recommend continuously using at low air flow 
and high temperature.

 Let the heating element be cooler after using a maximum 20 minutes. 

Ensure that it is placed back on its cooling stand to cool down between rework operations. Also, 
do not switch the hand tool on while it is in the cooling stand. 

Fail to comply with the 

instructions may result in damage to the hand tool. 

 

 

Do not aim the hot air at your eyes. 

Do not allow the hot air from the hand tool to aim the eyes 

as serious eye damage may occur.   

 

The hot air pencil can produce a lot of heat.

 Do not allow the heater and the nozzle to contact 

exposed  skin  as  burning  may  occur.  To  eliminate  the  possibility  of    burns,  allow  time  for  the 
equipment to cool before commencing maintenance.   

 

Death or serious injury may result from electric shock. 

It is therefore essential to isolate the 

equipment from the mains before commencing repairs.   

Содержание LF-853D

Страница 1: ...OPERATING MANUAL FOR LF 853D Multi Function SMD Rework System...

Страница 2: ...unauthorized alterations 1 Please unscrew the 4 screws under the bottom enclosure when the unit is used at the first time See the procedure on page13 2 Ensure the voltage rating of the unit and your p...

Страница 3: ...desoldering tip and the heating element are still remaining hot after being switched off Ensure that you do not touch the tips and the heating elements For your health do not inhale solder fumes You m...

Страница 4: ...he power cord must be unplug in before replacing the fuse in AC socket in rear side of the machine Do not unplug the power cord when the power switch is turned off the cooling system will begin to wor...

Страница 5: ...ssing keys SET at this time the iron which you set will enter the power off suspend status It means that the heater power is cut off If press then the heater power will be on OPTIONAL SMD TWEEZERS The...

Страница 6: ...ep Temperature 150 302 Temperature correction range 99 99 178 178 Default seting 150 302 F 1 000 F 2 00 F 3 000 F 4 Desoldering Power Consumption 170W Temperature range DIA 300 450 572 842 Sleep Tempe...

Страница 7: ...8 Temperature decreasing Down 9 Temp Display 10 Heat indicating light 11 SET Function key Desoldering Function Part 12 Temperature increasing UP 13 Temperature decreasing Down 14 Temp Display 15 Heat...

Страница 8: ...1 F 2 F 3 F 4 3 Password Setting When the LED displays F 1 and flashes press SET key one time and the unit enters the Password Set status At this moment the LED displays the pre set value Press or ke...

Страница 9: ...temperature of desoldering will go down to 200 392 and the LED displays at 200 and flashes Activating the solder wand will disengage the suspend status and the unit will immediately ramp up to the pr...

Страница 10: ...60 608 680 Operation for larger joint 370 400 698 752 Too low of a temperature will slow the flow rate of solder and may clog the tip Too a high temperature may burn the P C B Hot air function introdu...

Страница 11: ...ss SET key once to finish password setting and the unit will backup mode the user can continue set other modes or back from the setting mode 4 Fahrenheit and Centigrade Celsius temperature selection W...

Страница 12: ...in Solder and Desolder wands connect Vacuum tube to VAC Put the hot air gun to the holder 3 Connect AC power cord to mains In Let 4 Turn switch POWER SWITCH to ON position and the switch led will be...

Страница 13: ...may clog 3 Add solder to the joint of the component and allow the solder to melt completely for improved desoldering 4 Remove the solder collector and clean it after no more than 200 applications Howe...

Страница 14: ...orms it can be removed by careful buffing with 600 800 grit emery cloth isopropyl alcohol or equivalent and then the tinned areas with rosin core solder after the resin core has melted NEW TIPS Applyi...

Страница 15: ...process 4 Do not disassemble the pump If the pump or other critical internal components become faulty discontinue its use immediately Please return to your vendor or its authorized repairers for prop...

Страница 16: ...ply the proper quantity of solder paste and flux preferably no clean and place install the SMD on the PCB 2 Preheat SMD 3 Soldering Heat the lead frame evenly 4 Washing When soldering is completed was...

Страница 17: ...3 Unscrew the barrel nut assembly as in Figures 4 5 FIG 4 FIG 5 4 Remove the tip by using a pliers as in Figures 6 7 FIG 6 FIG 7 5 Insert the stainless tube of the tip back in the barrel to melt the...

Страница 18: ...ector as in Figure 11 CAUTION The solder collector is glass and thus retains heat handle with care FIG 11 3 Point the collector down while shaking slightly see Figure 12 and the waste solder will fall...

Страница 19: ...10 press turn red knob on the butt of iron 3 Remove solder collector see Figure 11 4 Disassemble the solder collector into 2 pars see Figures 15 16 FIG 15 FIG 16 5 Remove old cotton filter and replace...

Страница 20: ...months usage Maintenance for Desoldering Heater and Tip To prevent the desoldering tip being stuck by solder the desoldering tip has to be cleaned by a Probe after every time usage In such ways desol...

Страница 21: ...rocedure See Fig 3 SPARE PART Part No 79 460012 Heating element 120Vac 60Hz 600W Part No 79 560012 Heating element 230 240Vac 50Hz 600W INTERCHANGEABLE ACCESSORY 1 INTERCHANGEABLE TIPS Soldering tips...

Страница 22: ...21 Desoldering tips for DIA DIA100 2 INTERCHANGEABLE NOZZLES...

Отзывы: