background image

1

2

W A R R A N T Y

The YSI pH1200 instrument is warranted for two (2) year from date of purchase 
by the end user against defects in materials and workmanship, exclusive of 
batteries and any damage caused by defective batteries. pH1200 cable/
sensor assemblies are warranted for one (1) year from date of purchase by the 
end user against defects in material and workmanship. pH1200 instruments & 
cables are warranted for 90 days from date of purchase by the end user against 
defects in material and workmanship when purchased by rental agencies for 
rental purposes. Within the warranty period, YSI will repair or replace, at its 
sole discretion, free of charge, any product that YSI determines to be covered 
by this warranty.

To exercise this warranty, call your local YSI representative, or contact YSI 
Customer Service in Yellow Springs, Ohio at +1 937 767-7241, 800-897-
4151 or visit www.YSI.com for a Product Return Form. Send the product and 
proof of purchase, transportation prepaid, to the Authorized Service Center 
selected by YSI. Repair or replacement will be made and the product returned, 
transportation prepaid.  Repaired or replaced products are warranted for the 
balance of the original warranty period, or at least 90 days from date of repair 
or replacement.

LIMITATION OF WARRANTY

This Warranty does not apply to any YSI product damage or failure 
caused by: 
•  Failure to install, operate or use the product in accordance with 

YSI’s written instructions; 

•  Abuse or misuse of the product; 
•  Failure to maintain the product in accordance with YSI’s written 

instructions or standard industry procedure; 

•  Any improper repairs to the product; 
•  Use by you of defective or improper components or parts in 

servicing or repairing the product; 

•  Modification of the product in any way not expressly authorized 

by YSI.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED 
OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE. YSI’S LIABILITY UNDER 
THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT OF THE 
PRODUCT, AND THIS SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY 
FOR ANY DEFECTIVE PRODUCT COVERED BY THIS WARRANTY. 
IN NO EVENT SHALL YSI BE LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM 
ANY DEFECTIVE PRODUCT COVERED BY THIS WARRANTY.

Содержание YSI pH1200

Страница 1: ...OPERATIONS MANUAL pH1200 LABORATORY pH mV Temp Instrument English Espa ol Portugu s...

Страница 2: ...compensation n the pH NON AUTOLOCK mode 9 pH Measurements 9 Measurement with an ATC Temp probe in the pH AUTOLOCK mode 9 Measurement with manual temperature compensation in the pH AUTOLOCK mode 10 Me...

Страница 3: ...ent will be made and the product returned transportation prepaid Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days from date of repair or...

Страница 4: ...tic Temperature Compensation indicator will be displayed if a temperature probe is connected 12 EFF This will be displayed if the user is viewing the efficiency of the electrode It is recommended to u...

Страница 5: ...01 or 9 18 10 01 CALIBRATION WITH AN ATC TEMP PROBE IN THE PH AUTOLOCK MODE 1 Turn the unit on Press Clear key for 2 seconds all LCD elements will light up The meter clears all calibration values stor...

Страница 6: ...PROBE IN THE PH NON AUTOLOCK MODE 1 Turn the unit on Press Clear key for 2 seconds all LCD elements will light up The meter clears all calibration values stored in internal memory 2 Connect the pH el...

Страница 7: ...Temp probe to the ATC Temp connector of the unit ATC will light up 2 Press Mode key until pH and AUTO light up 3 Rinse the pH electrode and ATC temp probe with distilled water and immerse in the samp...

Страница 8: ...display the mV value of the sample T R O U B L E S H O O T I N G Error on Main Display Display Possible cause s Corrective Action s Er1 1 Stand was pressed before the electrode and ATC Temp probe sett...

Страница 9: ...cated metals When the time comes for you to recycle follow the easy steps outlined at ysi com BATTERY DISPOSAL The 1200 is powered by alkaline batteries which the user must remove and dispose of when...

Страница 10: ...ent for service The form may be downloaded from www ysi com by clicking on the Support N D I C E Garant a 17 C mo Empezar 18 Pantalla 18 Teclas 19 Selecci n del Juego de Soluciones Buffer 21 Calibraci...

Страница 11: ...trucciones escritas de YSI maltrato o uso indebido del producto incumplimiento del mantenimiento del producto conforme a las instrucciones escritas de YSI o el procedimiento est ndar de la industria t...

Страница 12: ...diciones normales de uso la tecla no se activar a menos que se mantenga pulsada durante 2 segundos para evitar que se borre accidentalmente la memoria almacenada Al pulsar la tecla Clear se encender n...

Страница 13: ...ompletado Si la primera soluci n buffer es 4 00 4 01 9 18 10 00 la unidad saldr autom ticamente en ese momento del modo de calibraci n La calibraci n de punto nico se ha completado 4 Enjuague las sond...

Страница 14: ...6 86 7 00 si realiza una calibraci n de puntos m ltiples Ajuste la lectura de la temperatura a la de la puntos m ltiples Ajuste la lectura de la temperatura a la de la primera soluci n buffer usando l...

Страница 15: ...dici n El icono WAIT espere parpadear La unidad est esperando una lectura estable La pantalla rastrear el valor de pH seg n lo medido por el electrodo de pH y la sonda ATC Temp 5 Cuando desaparezca el...

Страница 16: ...I N D E P R O B L E M A S Error Posible Causa Acci n correctiva Er1 1 El bot n stand fue presionado antes que el electrodo y la compensaci n de temperatura estabilicen a 1 5 pH del valor del buffer 2...

Страница 17: ...atorio 605170 Stand para electrodo 603824 Caja de buffers de pH 2 pintas de cada uno 4 7 y 10 R E C I C L A J E YSI se compromete a reducir el impacto medioambiental que produce su actividad Aunque la...

Страница 18: ...volver un producto para su mantenimiento o reparaci n incluya el formulario de devoluci n del producto con su certificado de limpieza El formulario debe completarse en su totalidad para que un centro...

Страница 19: ...scritas da YSI Neglig ncia ou m utiliza o do produto Falha em manter o produto de acordo com as instru es escritas da YSI ou com os procedimentos normais do sector Quaisquer repara es indevidas no pro...

Страница 20: ...e ser novamente calibrada antes de ser utilizada Up Down As duas teclas s o utilizadas manualmente para inserir os valores da temperatura N o t m efeito na unidade quando esta operada em modo ATC Stan...

Страница 21: ...enha premida a tecla Meas Effic durante cerca de 3 segundos para visualizar a efici ncia do novo el ctrodo CALIBRA O COM COMPENSA O MANUAL DA TEMPERATURA NO MODO PH AUTOLOCK 1 Ligue a unidade Prima a...

Страница 22: ...ado permanece aceso enquanto os dois tamp es restantes ficam intermitentes A unidade est pronta para ser inclinada no segundo tamp o Nota Se a primeira solu o tamp o for 6 86 7 00 nesse momento prima...

Страница 23: ...o com uma sonda ATC Temp no modo pH NON AUTOLOCK M E D I E S D E T E M P E R AT U R A O pH1200 pode medir temperaturas de modo independente com a sonda ATC temp sem utilizar o el ctrodo de pH Coloque...

Страница 24: ...14 00 2 MV medido estiver fora da faixa de mV 1 999 9 1999 9 3 Temperatura medido est fora da faixa 0 0 100 0 C 1 Trazer pH da amostra para a faixa de medi o correta 2 Trazer amostra ORP para a faixa...

Страница 25: ...maneira respons vel com os materiais no final de um ciclo de vida longo e produtivo O programa de reciclagem da YSI certifica se de que o equipamento antigo processado de uma maneira ecol gica reduzin...

Страница 26: ...Item 601204REF Rev A October 2012 2012 YSI Inc Xylem Inc...

Отзывы: