Xylem WTW SenTix H Скачать руководство пользователя страница 3

SenTix

®

Technical data

3

ba75739e02

07/2013

Technical data

General data

Measurement and application characteristics

Shaft dimensions, shaft material, electrical connection

* Connection cable not included in the scope of delivery of the combination 
electrode (see W

EAR

 

PARTS

 

AND

 

ACCESSORIES

)

** Coaxial plug according to DIN 19262

WTW model

Reference electro-
lyte

Junction

NTC

Special features

SenTix

®

 H

KCl 3 mol/L, Ag

+

 free Ground

No

Adjustable ground junc-
tion

SenTix

®

 HW

KCl 3 mol/L, Ag

+

 free Ground

No

Adjustable ground junc-
tion

SenTix

®

 HWD

KCl 3 mol/L, Ag

+

 free Ground

Yes

WTW model

pH measur-
ing range

Allowed tempera-
ture range

Membrane resis-
tance at 25 °C

Typical application

SenTix

®

 H

0 ... 14

0 ... 80 °C

< 2 GOhm

Highly alkaline and 
highly saltine solutions

SenTix

®

 HW

0 ... 14

0 ... 60 °C

< 800 MOhm

Solutions with low ion 
contents, emulsions, 
suspensions

SenTix

®

 HWD

0 ... 14

-5 ... 100 °C

< 600 MOhm

WTW model

Shaft

Electrical connection

Length 
[mm]

Ø

 [mm]

Material

Combination 
electrode 
connection

Meter connection Cable 

length

SenTix

®

 H

170

12

Glass

S7 plug-in 
connector

depending on S7 cable*

SenTix

®

 HW

170

12

Glass

S7 plug-in 
connector

depending on S7 cable*

SenTix

®

 HWD

170

12

Glass

Fixed cable

DIN** + banana

1 m

Содержание WTW SenTix H

Страница 1: ...OPERATING MANUAL ba75739e02 07 2013 SenTix PH COMBIN ELECTRODES WITH LIQUID REFERENCE SYSTEM AND GROUND JUNCTION SenTix H SenTix HW SenTix HWD...

Страница 2: ...opyright Weilheim 2013 WTW GmbH Reproduction in whole or even in part is prohibited without the express written permission of WTW GmbH Weilheim Printed in Germany For the most recent version of the ma...

Страница 3: ...round No Adjustable ground junc tion SenTix HWD KCl 3 mol L Ag free Ground Yes WTW model pH measur ing range Allowed tempera ture range Membrane resis tance at 25 C Typical application SenTix H 0 14 0...

Страница 4: ...for the combination electrode to be stored Always keep the watering cap clean Connect the combination electrode to the meter Calibrate the combination electrode according to the operating manual of th...

Страница 5: ...olyte solu tion comes out Calibration and measurement General rules Make sure the refilling opening for the reference electrolyte solution is open Avoid the displacement of any solution sample or buff...

Страница 6: ...ning Note pH combination electrodes must not be stored dry or in deionized water The combination electrode could be permanently damaged by this If the liquid in the watering cap has dried up condition...

Страница 7: ...the tip of the dropping bottle into the refilling opening while turning it slightly Pump the reference electrolyte in the shaft using the dropping bottle Pull the dropping bottle out of the refilling...

Страница 8: ...lectrolyte solution for at least 1 hour Then recalibrate the combi nation electrode Wear parts and accessories Note Detailed information on our wide range of buffer solutions and more acces sories is...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...water needs Developing new technologies that will improve the way water is used conserved and re used in the future is central to our work We move treat analyze and return water to the environment and...

Отзывы: