background image

Xylem Analytics Germany GmbH
Am Achalaich 11
82362 Weilheim
Germany

Xylem Analytics Germany
Sales GmbH & Co. KG
WTW
Am Achalaich 11
82362 Weilheim
Germany

Tel.:
Fax:
E-Mail
Internet:

+49 881 183-325
+49 881 183-414
[email protected]
www.xylemanalytics.com

Service and Returns:

®

1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.

We're a global team unified in a common purpose: creating advanced technology solutions to the world's
water challenges. Developing new technologies that will improve the way water is used, conserved, and re-
used in the future is central to our work. Our products and services move, treat, analyze, monitor and return
water to the environment, in public utility, industrial, residential and commercial building services settings.
Xylem also provides a leading portfolio of smart metering, network technologies and advanced analytics
solutions for water, electric and gas utilities. In more than 150 countries, we have strong, long-standing
relationships with customers who know us for our powerful combination of leading product brands and
applications expertise with a strong focus on developing comprehensive, sustainable solutions.

For more information on how Xylem can help you, go to www.xylem.com.

Xylem |

m|

ˈ ə

zīl

Содержание WTW FCML 412-M12 Series

Страница 1: ...OPERATING MANUAL ba77197e02 01 2024 FCML 412 N S FCML 412 M12 x pH INDEPENDENT SENSOR FOR FREE CHLORINE FCML 412 N FCML 412 N S FCML 412 M12 x...

Страница 2: ...FCML 412 N S FCML 412 M12 2 ba77197e02 01 2024 Copyright 2024 Xylem Analytics Germany GmbH Printed in Germany...

Страница 3: ...ing the membrane cap with electrolyte solution 8 3 3 Electrical connection 10 3 4 Installation in the flow through vessel D CL 10 3 5 Installation in the flow through vessel D 19 11 4 Measurement Oper...

Страница 4: ...es all the free chlorine present sum of gaseous dissolved chlorine 1 Connection FCML 412 N PG7 gland FCML 412 N S Screw plug in coupling for connection cable AK CL FCML 412 M12 Flange plug for adapter...

Страница 5: ...y of the measuring transmitter and for the transmission of measurement signals 4 20 mA current signal FCML 412 N S The FCML 412 N S sensor has a four pin socket for connection to the measuring transmi...

Страница 6: ...t be damaged if the actions mentioned are not taken 2 1 2 Safety signs on the product Note all labels information signs and safety symbols on the product A warning symbol triangle without text refers...

Страница 7: ...d unauthorized 2 2 2 Requirements for safe operation Note the following points for safe operation The product may only be operated according to the authorized use spec ified above The product may only...

Страница 8: ...ectrolyte solution NOTE Risk of damage for the sensor in the case of improper handling Do not touch the electrode finger with your fingers Do not apply pressure to the membrane disk Do not unscrew the...

Страница 9: ...ap while doing this Then screw the electrode shaft into the membrane cap For this first turn the elec trode shaft anti clockwise until the thread catches then slowly screw in the electrode shaft as fa...

Страница 10: ...rough vessel D CL The flow through vessel D CL is optimized for the FCML 412 N S chlorine sensors Proceed as follows to install the sensor The position in the flow through vessel has a considerable ef...

Страница 11: ...gh vessel D 19 The flow through vessel D 19 is optimized for the FCML 412 M12 chlorine sensor 1 Top edge of the coupling ring 2 Above the middle of the inlet opening 3 Lower edge of the groove 4 Top e...

Страница 12: ...le effect on the approach flow and hence the measuring function of the sensor Therefore carefully position the sensor as described below 1 Connect the ADA CL IDS adapter to the M12 flange plug and scr...

Страница 13: ...or with the top edge 2 of the cou pling ring 5 Tighten the coupling ring by hand 6 Tighten the coupling ring approx a quarter turn further with the M32 assembly wrench Make sure the sensor is firmly a...

Страница 14: ...libration of the chlo rine sensor is carried out as a single point calibration The calibration value nominal value is usually determined photometrically A common procedure for this is the DPD method f...

Страница 15: ...e opening 2 Hose ring NOTE Negative pressure in the membrane cap can destroy the membrane disk Therefore make sure the valve opening is not inadvertently closed by your fingers while unscrewing the me...

Страница 16: ...the electrolyte solution and or membrane cap the sensor has to be repolarized see section 4 1 RUN IN PERIOD If calibration is still not possible after cleaning the measurement electrode change the me...

Страница 17: ...orine sensor FCML 412 including 1x membrane cap M48 100 ml electrolyte solution ELY FCML 412 N Polishing strip ZBK FCML 412 N 205 246 Adapter for connecting the sensor FCML 412 M12 to an IDS interface...

Страница 18: ...ct accessories or literature indicates that the product should not be disposed of with other waste at the end of its working life To prevent possible harm to the environment or human health from uncon...

Страница 19: ...bration proce dure Single point calibration e g with photometric measurement according to the DPD 1 method as a reference 7 2 Application characteristics Temperature range 0 45 C 32 113 F The measurem...

Страница 20: ...drophilic membrane Electrolyte ELY FCML 412 N from ZBK FCML 412 N Material 200 mm 175 mm 25 mm 25 mm FCML 412 N FCML 412 N S 175 mm 25 mm FCML 412 M12 x 37 mm Shaft PVC Membrane cap PVC Membrane holde...

Страница 21: ...Output signal 4 20 mA FCML 412 N S 4 wire connection via AK CL cable by means of screwed connection plug connection 6 12 V DC power supply by the measuring transmitter Nominal slope approx 100 mV per...

Страница 22: ...Technical data FCML 412 N S FCML 412 M12 22 ba77197e02 01 2024...

Страница 23: ......

Страница 24: ...rove the way water is used conserved and re used in the future is central to our work Our products and services move treat analyze monitor and return water to the environment in public utility industr...

Отзывы: