Manual Ozone Generating System
SMOevo
PLUS
Troubleshooting
Manual_SMOevoPLUS_eng_01.2019.doc
page 156 of 179
Message
No.
Message shown on the display
Description /
Possible Cause
Countermeasures
226
PSU:AI200 Warning temperature step-up
transformer primary coil high
Temperature step-up transformer
>120 °C
Temperature in control cabinet too
high
Temperature Ambient too high
Check transformer fan
Check function of cooling unit
Check transformer
Contact regional Wedeco customer
service.
Refer to Chapter Contact
Addresses
229
PSU:AI202 Alarm temperature step-up
transformer ferrite core high
Temperature step-up transformer
>120 °C
Temperature in control cabinet too
high
Temperature Ambient too high
Check transformer fan
Check function of cooling unit
Check cables and connections
Check transformer
Contact regional Wedeco customer
service.
Refer to Chapter Contact
Addresses
230
PSU:AI202 Warning temperature step-up
transformer ferrite core high
Temperature step-up transformer
>120 °C
Temperature in control cabinet too
high
Temperature Ambient too high
Check transformer fan
Check function of cooling unit
Check transformer
Contact regional Wedeco customer
service.
Refer to Chapter Contact
Addresses
•
If the alarm message occurs again after restarting the ozone system, contact your regional Wedeco Service.
Refer to Chapter Contact Addresses.