Troubleshooting
Manual_SMOevoPLUS_eng_01.2019.doc
page 148 of 179
Message
No.
Message shown on the display
Description /
Possible Cause
Countermeasures
78
PSU:DI21.5 Alarm fault power supply 24V
PSU 24V internal fault message.
Automatic circuit breaker upstream
mains unit triggered.
Refer to manufacturer’s manual.
Check cables and connections.
Check automatic circuit breaker.
Check mains voltage.
97
Alarm communication fault to Remote-IO
SYS
PLC internal fault message.
Cable break,
Incorrect wiring.
24 V power supply to Remote-IO is
missing.
Check cables and connections.
Check input voltage.
Contact Wedeco Service / Fault
rectification only by qualified staff.
Refer to Chapter Contact Addresses
.
98
Alarm communication fault to Remote-IO
PSU
PLC internal fault message.
Cable break,
Incorrect wiring.
24 V power supply to Remote-IO is
missing.
Check cables and connections.
Check input voltage.
Contact Wedeco Service / Fault
rectification only by qualified staff.
Refer to Chapter Contact Addresses
.
103
Alarm communication fault to MOCP
Communication problems.
Communication processors
defective.
Cables defective.
Contact regional Wedeco Service.
Refer to Chapter Contact Addresses.
104
Alarm shutdown by MOCP
Fault message from main control.
Investigate customer problem and
rectify.
Acknowledge fault.