07.0.15
Ball valve
Isolation valve for PI310-2
PI310-1
07.0.20
Pressure
indicator
Displays cooling water inlet pressure
FT/FSL310
07.0.25
Flow meter
Indicates cooling water flow rate and transmitts value to PLC.
The system will shut down if the set flow value is underrun by
40% and triggers a fault message.
BV310-7
07.0.30
Drain valve
To drain water from the cooling water system.
PRV310-2
07.0.35
Pressure
relieve valve
Opens in case maximum cooling water pressure is exceeded.
Set at 3.5bar (50psig).
The setting of the safety valve must not be changed at
any time!
TT310-2
07.0.40
Temperature
transmitter
(redundant)
Compulsory safety element for the ozone generator making
the system shut down both via PLC and hard-wired if the
temperature exceeds 50°C.
The setting of the temperature transmitter must not be
changed at any time!
BV310-8
07.0.45
Ball valve
Isolation valve for PI310-3
PI310-3
07.0.50
Pressure
indicator
Indicates cooling water outlet pressure
BV310-9
07.0.55
Ball valve
Drain valve to vent all air from the water cooling system during
commissioning or in case of maintenance or service. Must be
fully closed during normal operation.
CV310-2
07.0.60
Actuated
butterfly
valve
Cooling water outlet control valve. Opens/closes upon
start/stop with the system.
BFV310-2
07.0.65
Butterfly
valve
Customer interface for cooling water return. Used to control
the cooling water flow through the ozone generator, if
necessary.
BV310-10
07.0.70
Ball valve
Inlet isolation valve for converter cooling cycle. Must b efull
yopen during normal operation
FSL310
07.0.75
Flow
meter/flow
switch
To display the flow. The flow meter is equipped with reed
contact which switches off the system and triggers a fault
message if the value falls below 2l/min (set point = 4l/min).