QUICK GUIDE

WQG-10029-01

Front Panel Display and Buttons

The display is an eight digit transmissive red LCD, 
0.46” high. A green LCD is also available. For 
outdoor or high ambient light conditions, reflective 
readouts will be supplied.

SELECT: Toggles display and advances menu 
selection in the programming mode.

RESET: Resets counter to zero if enabled and 
changes display in programming mode.

COUNT DISPLAY: 8-digit, display flashes “tot” over 
for an overflow condition.

RATE DISPLAY: 6-digit with an enunciator “R” on the 
left side.

Memory

Non-volatile E2PROM memory retains all 
programming parameters and the count value when 
power is removed.

Act-Pak® Electronic Instrumentation

Models 1100D and 1100DN Quick Guide

Electrical Connections

1.  Complete all connections to the metering device 

and instrument before applying power.

2.  If it becomes necessary to disconnect any of these 

connections, first remove the AC power to the 
instrument.

Meter or Signal Output

Terminal 

Number

Function

Wire Color 

Switch Inputs 

(Belden 8760)

Wire Color Solid 

State Inputs 

(Belden 8770)

13

+12VDC

No Connection

Red

16

Input Signal

White

White

14

Ground

Black

Black

15

Shield

Bare (Shield)

Bare (Shield)

Act-Pak® Remote Monitoring is an automatic control translator package. The Model 1100D 
is a standard NEMA1 free standing or panel mountable enclosure. The Model 1100DN is 
a NEMA4X wall mountable fiberglass enclosure. Each Act-Pak device accepts pulses or 
contact closures from metering devices and provides a variety of outputs.

Physical Size/Weight

Model

1100D

1100DN

Length

8-3/4” (22 cm)

8-1/2” (21.6 cm)

Height

3-1/8” (8 cm)

4-1/4” (11 cm)

Width

8-9/16” (23 cm)

6-1/2” (16.5 cm)

Weight

4 lbs. (1.8 kg)

4 lbs. (1.8 kg)

Typical Series 1100 Act-Pak Wiring Connection Diagram

Содержание SENSUS Act-Pak 1100D

Страница 1: ...o the metering device and instrument before applying power 2 If it becomes necessary to disconnect any of these connections first remove the AC power to the instrument Meter or Signal Output Terminal Number Function Wire Color Switch Inputs Belden 8760 Wire Color Solid State Inputs Belden 8770 13 12VDC No Connection Red 16 Input Signal White White 14 Ground Black Black 15 Shield Bare Shield Bare S...

Страница 2: ...17 VAC All resistive loads Option C1 SS 50 mA at 24 VDC Typical Series 1100 Act Pak Wiring Connection Diagrams AC Power Inputs Terminal Number Function 3 Earth Ground 2 117 VAC 1 117 VAC Proportional Output Terminal Number Function 5 Positive 6 Negative Option B Terminal Number Function 10 Normally Closed Contact 11 Common 12 Normally Open Contact Option C1 C1 SS Terminal Number Function Relay Fun...

Страница 3: ...ext digit To start the least significant digit flashing momentarily depress the RST button To exit the programming mode and save all parameters step through the module until one of the four main modules is displayed then press the RST button until Pro nO displays Pressing the SEL button at this point enters the data and closes the program mode Program Menus Module 1 1 inPUt InP A b dual cnt CntA d...

Страница 4: ... a contact closure based on the flow rate set to rATE For pulsed outputs based on total set to Count A SPt ACT If rate was selected above to bound if contacts are to close when the setpoint is exceeded Act Pak Electronic Instrumentation Models 1100D and 1100DN Quick Guide and open below the setpoint To latch or hold the contacts closed once the flow rate is exceeded set to LAtCH A manual reset is ...

Страница 5: ...t binary number from the chart that does not exceed the balance continue selecting and subtracting until the balance equals zero At this point all factors subtracted must be set into the instrument by placing the associated switch in the ON position Act Pak Electronic Instrumentation Models 1100D and 1100DN Quick Guide Adjusting Option M Multiplier The multiplier circuit is configured in binary co...

Страница 6: ...caution when working with disassembled AC electrical components Act Pak Electronic Instrumentation Models 1100D and 1100DN Quick Guide Calibration Proportional Output 4 20 mA with a Voltmeter 1 Connect a load resistor across terminals 5 and 6 2 This resistor may be of any value less than or equal to 500 ohms 3 Connect a digital voltmeter across terminals 5 and 6 4 Apply power to the instrument wit...

Страница 7: ... circuit board 3 Note that the AC line cord is attached to terminals 1 2 and 3 4 Use the tables in the manual to connect the meter and control devices 5 To attach wires loosen the appropriate screw on the connector 6 Run the wires through the enclosure and place in the opening on the connector at the proper location and tighten the screw 7 Do not leave bare wires extending outside the connector 8 ...

Отзывы: