background image

6

Best practice: Use two stainless 
steel hose clamps to attach hose to 
hose barb.

During the winterization of a vessel, it’s recommended that you remove the check valve (if equipped) and drain any residual 
water from the plumbing.

Plumbing:

This bilge pump has been designed to be used with 

ŷ

exible hose. Rigid piping or tubing may damage the pump or the pump’s 

discharge.

*

actors that reduce the 

ŷ

ow of a bilge pump may include but are not limited to the following:

The length of discharge piping (longer runs reduce 

ŷ

ow)

The number or radius of bends

The roughness of the interior surfaces of piping and 

Ŷ

ttings (smooth bore hose is best)

The reduction (hose restriction) in cross-sectional area of discharge system components such as check valves and 
thru-hulls

Attach the discharge hose to the hose barb using stainless steel hose clamps.  
The thru-hull discharge 

Ŷ

tting should be mounted at least 8

ŕ

 (2

.3 cm) above the heeled water line to prevent water 

siphoning in from outside the vessel or the discharge may be located below the maximum heeled waterline if the 

discharge line is provided with both of the following:

A seacock installed in accordance with the requirements of ABYC H-27, Seacocks, Thru-Hull Connections, and 

Drain Plugs, and

A vented loop or other means to prevent siphoning into the boat. A check valve shall not be used for this purpose.

-

f the discharges of several pumps are manifolded to discharge through a single thru-hull 

Ŷ

tting, the system shall be 

designed so that the operation of one pump will not back feed another pump, and the simultaneous operation of each 

pump will not diminish the pumping capacity of the system. A check valve shall not be used in the discharge manifold 
system.
A check valve may be used only when necessary to prevent an automatic bilge pump from cycling on and off due to back 

ŷ

ow from the discharge line.

Hose connections shall be secured with a non-corrosive type of clamp, or be mechanically fastened with permanently 

attached end 

Ŷ

ttings, such as swaged sleeve. Threaded inserts shall be attached with corrosion resistant metallic clamps.

Please note that the check valve should NOT be used 
with the elbow 

Ŷ

tting. The check valve and elbow 

combination greatly restrict the 

ŷ

ow.

Содержание rule LoPro 4708856181

Страница 1: ...Manual Bilge Pump INSTRUCTION MANUAL...

Страница 2: ...ries User safety DANGER This product is not intended for damage control or to deal with ooding resulting from hull damage This product is intended to be used in Bilge Pumping Systems for small craft w...

Страница 3: ...manufacturer instructions and in an accessible location to permit servicing and cleaning of the intake and or screening Onboatswithanenclosedaccommodationcompartment anaudiblealarmshallbeinstalledindi...

Страница 4: ...4 7 5 Amp Fuse Positive 7 5 Amp Fuse 7 5 Amp Fuse MANUAL PWR AUTO ON OFF Brown Brown Brown positive Float switch Panel switch Float switch only Panel switch only Black Ground Black Ground Black Ground...

Страница 5: ...inless Steel screws of an adequate length as to secure the pump but not penetrate the entire thickness of the hull Use a exible sealant in the screw holes to prevent water from penetrating the screw h...

Страница 6: ...below the maximum heeled waterline if the discharge line is provided with both of the following A seacock installed in accordance with the requirements of ABYC H 27 Seacocks Thru Hull Connections and...

Страница 7: ...ngHoles 1 8 4 5cm MountingHoles 2 35 5 9cm 4 10 2cm 4 86 12 3cm 2 4 6 1cm Dimensional Drawing Flow Curves 0 2 4 6 8 10 12 14 0 100 200 300 400 500 600 700 800 900 Head Ft H20 Flow GPH Performance at 1...

Страница 8: ...SO 88 2 3 Electrically Operated DC Bilge Pumps SO 1 133 2 12 Extra Low Voltage D C nstallations SO 15 83 2 3 Bilge Pumping Systems This product is intended to be used in Bilge Pumping System for small...