The following is a summary of typical wiring installations:

Disconnect power before installing or servicing the pump.
Our pump is equipped with silicone blocked, tin coated 16 gauge wire. Please follow the table below when extending 

the wires.

This pump must be fused with a 7.5 amp fuse (not included).

All potential sources of ignition located in spaces containing gasoline powered machinery or gasoline fuel tank(s), or joint 

Ŷ

tting(s), or other connection(s), between components of a gasoline system, shall be ignition protected in accordance with 

the requirements of ABYC E-11, AC and DC Electrical Systems On Boats.
The electrical wiring, connections, and installation shall be in accordance with the requirements of ABYC E-11, AC and DC 
Electrical Systems On Boats.

Electrical

Brown wire

Black wire

Positive

Ground

Wire Size Table

 Total Wire Length (positive to pump) - feet (meters)

0-15 ft 

15 - 20 ft 

20 - 30 ft 

30 - 60 ft 

  60 - 90 ft

0-4.5 m 

(4.5 - 6 m) 

(6 - 9 m) 

(9 - 18 m) 

(18 - 27 m)

16 AWG 

14 AWG 

12 AWG 

10 AWG 

  8 AWG

(1.5 mm

2

) (2.5 

mm

2

) (4 

mm

2

) (6 

mm

2

) (10 

mm

2

)

Bilge pumps shall be mounted in accordance with the pump manufacturer instructions, and in an accessible location to 
permit servicing and cleaning of the intake and/or screening.
On boats with an enclosed accommodation compartment, an audible alarm shall be installed indicting that the bilge water 
is approaching the maximum bilge water level. 
Bulkhead penetrations shall be in accordance with the requirements of ABYC H-2, Ventilation of Boats Using Gasoline, to 
minimize the potential for migration of carbon monoxide from machinery compartments containing gasoline engines to 
adjacent accommodation compartments.
Potential electrical sources of ignition located in spaces containing gasoline powered machinery, or gasoline fuel tank(s), 
or joint 

Ŷ

tting(s), or other connection(s) between components of a gasoline system, shall be ignition protected, unless the 

component is isolated from a gasoline fuel source as described in ABYC E-11.5.3.3

Exception:

1. 

Boats using diesel fuel as the only fuel source.

2. 

Outboard engines mounted externally or in compartments open to the atmosphere in accordance with the 
requirements of ABYC H-2, Ventilation of Boats Using Gasoline.

The bilge pump inlet shall be located so that excess bilge water can be removed from the bilge at static 

ŷ

oating position, 

and at maximum conditions created by the boat’s motion, heel, and trim.

Содержание rule LoPro 4708856181

Страница 1: ...Manual Bilge Pump INSTRUCTION MANUAL...

Страница 2: ...ries User safety DANGER This product is not intended for damage control or to deal with ooding resulting from hull damage This product is intended to be used in Bilge Pumping Systems for small craft w...

Страница 3: ...manufacturer instructions and in an accessible location to permit servicing and cleaning of the intake and or screening Onboatswithanenclosedaccommodationcompartment anaudiblealarmshallbeinstalledindi...

Страница 4: ...4 7 5 Amp Fuse Positive 7 5 Amp Fuse 7 5 Amp Fuse MANUAL PWR AUTO ON OFF Brown Brown Brown positive Float switch Panel switch Float switch only Panel switch only Black Ground Black Ground Black Ground...

Страница 5: ...inless Steel screws of an adequate length as to secure the pump but not penetrate the entire thickness of the hull Use a exible sealant in the screw holes to prevent water from penetrating the screw h...

Страница 6: ...below the maximum heeled waterline if the discharge line is provided with both of the following A seacock installed in accordance with the requirements of ABYC H 27 Seacocks Thru Hull Connections and...

Страница 7: ...ngHoles 1 8 4 5cm MountingHoles 2 35 5 9cm 4 10 2cm 4 86 12 3cm 2 4 6 1cm Dimensional Drawing Flow Curves 0 2 4 6 8 10 12 14 0 100 200 300 400 500 600 700 800 900 Head Ft H20 Flow GPH Performance at 1...

Страница 8: ...SO 88 2 3 Electrically Operated DC Bilge Pumps SO 1 133 2 12 Extra Low Voltage D C nstallations SO 15 83 2 3 Bilge Pumping Systems This product is intended to be used in Bilge Pumping System for small...

Отзывы: