1. General 

 

1.1. Foreword 

This product corresponds with the requirements of the 
Machine directive 2006/42/EC. 

 

The staff employed on installation, operation, in-
spection and maintenance must be able to prove 
that they know about the relevant accident preven-
tion regulations and that they are suitably qualified 
for this work. If the staff does not have the relevant 
knowledge, they should be provided with suitable 
instruction. 

 

The operating safety of the pumps or units (i.e. pump plus 
motor) supplied is only guaranteed if these are used in 
accordance with the provisions given in the Confirmation 
of Order and/or Point 

6 in “Installation” 

The operator is responsible for following the instructions 
and complying with the safety requirements given in these 
Operation Instructions. 
Smooth operation of the pump or pump unit can only be 
achieved if installation and maintenance are carried out 
carefully in accordance with the rules generally applied in 
the field of mechanical and electrical engineering. 
If not all the information can be found in these Operating 
Instructions, please contact us. 
The manufacturer takes no responsibility for the pump or 
pump unit if the Operating Instructions are not followed. 
These Operating Instructions should be kept in a safe 
place for future use. 
If this pump or pump unit is handed on to any third party, it 
is essential that these Operating Instructions and the op-
erating conditions and working limits given in the Confir-
mation of Order are also passed on in full. 
These Operating Instructions do not take into account all 
design details and variants nor all the possible chance oc-
currences and events which might happen during installa-
tion, operation and maintenance. 
Alterations or changes to the machine are only permitted 
by agreement with the manufacturer. Original spare parts 
and accessories authorized by the manufacturer should 
be used for greater safety. We bear no responsibility for 
the consequences of using other parts. 
We retain all copyright in these Operating Instructions; 
they are intended only for personal use by the owner of 
the pump or the pump unit. The Operating Instructions 
contain technical instructions and drawings which may 
not, as a whole or in part, be reproduced, distributed or 
used in any unauthorized way for competitive purposes or 
passed on to others. 
 

1.2. Guarantee 

The guarantee is given in accordance with our Conditions 
of Delivery and/or the confirmation of order. Repair work 
during the guarantee period may only be carried out by 
us, or subject to our written approval. Otherwise the guar-
antee ceases to apply. 

Longer-therm guarantees basically only cover correct 
handling and use of the specified material. Wear and tear, 
parts that are subject to wear such as impellers, mechani-
cal seals or packing, shaft seals, shafts, shaft sleeves, 
bearings, split rings and wear rings etc., as well as dam-
age caused during transport or as a result of improper 
storage are not covered by the guarantee. In order for the 
guarantee to apply, it is essential that the pump or pump 
unit is used in accordance with the operating conditions 
given on the type plate, confirmation of order in the Data 
Sheet. This applies particularly for the endurance of the 
materials as well as the smooth running of the pump. If 

one or more aspects of the actual operation conditions are 
different, we should be asked to confirm in writing that the 
pump is suitable.   

 

1.3. Safety regulations 

These Operating Instructions contain important instruc-
tions which must be followed when the pump is assem-
bled and commissioned and during operating and mainte-
nance. 
For this reason, these Operating Instructions must be 
read by the skilled staff responsible and/or by the operator 
of the plant before it is installed and commissioned, and 
they must be left permanently ready at hand at the place 
where the plant is in use. The operator must ensure that 
the contents of the Operating Instructions are fully under-
stood by the staff. These Operating Instructions do not 
refer to the General Regulations on Accident Prevention 
or local safety and/or operating regulations. The operator 
is responsible for complying with these (if necessary by 
calling in additional installation staff). 
The safety instructions contained in these Operating In-
structions have the following special safety markings as 
specified in DIN 4844: 

Safety reference! 

Non-observance can impair the pump and its func-
tion. 
 

General Symbol for Danger! 

Persons can be endangered. 
 

Warning of electric voltage! 

 
 
It is absolutely essential that safety information affixed di-
rectly to the pump or pump unit is followed and main-
tained so that it is always easily legible.  
 

1.4. Safety instructions 
Dangers of not following safety instructions  

Failure to follow the safety instructions can result in the 
following, for example:  

  People being at risk because of electrical, mechan-

ical an chemical factors. 

  Important functions of the pump of pump unit fail-

ing.  

 

Safety instructions for the operator 

  Depending on the operating conditions, wear and 

tear, corrosion or age will limit the working life of 
the pump/pump unit, and its specified characteris-
tics. The operator must ensure that regular inspec-
tion and maintenance are carried out so that all 
parts are replaced in good time which would oth-
erwise endanger the safe operation of the system. 
If abnormal operation or any damaged are ob-
served, the pump must cease operation immedi-
ately. 

  If the breakdown or failure of any system or unit 

could lead to people being hurt or property being 
damaged, such system or unit must be provided 
with alarm devices and/or spare modules, and they 
should be tested regularly to ensure that they func-
tion properly. 

  If dangerous media (e.g. explosive, toxic, hot) leak 

out (e.g. from shaft seals), these must be directed 
away so that there is no danger to people or the 

Содержание Lowara SEKAMATIK 200 E UF

Страница 1: ...Liste 5357 1 BA Dezember 2014 Montage und Bedienungs anleitung Installation and Operation Instruction Manual Baureihe Series SEKAMATIK 200 E UF...

Страница 2: ...Declaration of Conformity valid only for XYLEM Service Austria GmbH aggregate supplied in is entirety according to EC Machinery Directive 2006 42 EC Appendix IIA Hersteller XYLEM Service Austria GmbH...

Страница 3: ...2 3 Technische Daten 5 2 4 Betriebsbedingungen 5 2 5 Explosionsgef hrdete Bereiche 5 3 Garantie 5 4 Transport und Lagerung 5 5 Elektroanschluss 5 5 1 Allgemeines 5 5 2 Phasenvertauschung 6 6 Montage u...

Страница 4: ...ring dichtungen oder Packungsstopfbuchsen Wellendichtrin ge Wellen Wellenschutzh lsen Lager Spalt und Schlei ringe usw weiters durch Transport oder unsach gem e Lagerung verursachte Sch den Voraussetz...

Страница 5: ...ne Abdeckplatte 3 Zul ufe DN 100 ei nen Druckleitungsanschluss und einen DN 70 Anschluss stutzen f r Entl ftungs und Kabelrohr Die Pumpen eignen sich zum F rdern von sauberem und verschmutztem Wasser...

Страница 6: ...h lter ffnen Beide Leitungen mit Steckmuffe und einem eingelegten O Ring verbinden Die Entl ftungsleitung muss stetig steigend installiert werden Die Druckleitung zum Kanalanschluss an das Gewinde des...

Страница 7: ...nd Laufrad auf sichtbaren Verschlei pr fen ggf austauschen Wellenlager durch Drehen der Welle auf freien und ge r uschlosen Lauf pr fen Bei Sch den ist eine General berholung durch eine XYLEM Fachwerk...

Страница 8: ...n 10 2 3 Technical Data 10 2 4 Operation Conditions 10 2 5 Explosive Environments 10 3 Warranty 10 4 Transport and Storage 10 5 Electrical Connection 10 5 1 General 10 5 2 Check of Direction of Rotati...

Страница 9: ...bearings split rings and wear rings etc as well as dam age caused during transport or as a result of improper storage are not covered by the guarantee In order for the guarantee to apply it is essenti...

Страница 10: ...the floor level is odour tight The pumps must not be used for pumping of liquids containing great quantities of abrasive solids like sand or stones Before pumping of chemically aggressive liquids the...

Страница 11: ...e pneumatic level control the pump starts aud stops according to the liquid level in the tank 8 Maintenance and Repair In case of a defect of the pump a repair shall be car ried out only by the manufa...

Страница 12: ...annual maintenance Servicing Contract For a regular expert execution of all necessary mainte nance and inspection we recommend the conclusion of a servicing contract by our XYLEM Service 9 Warranty Re...

Страница 13: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 11 Order Sheet for Spare Parts To XYLEM Water Solutions Austria GmbH A 2000 Stockerau Ernst Vogel Strasse 2 Fax 0043 2266 65311 Pump ty...

Страница 14: ...odenablauf 3 01 Rost 3 02 Senk Schraube 3 03 U Bogen 4 01 Doppelnippel 4 02 O Ring 4 03 Einschraubteil mit O Ring 5 01 Einbaugarnitur 8 01 Pumpe 13 Spare part list ATTENTION The following list contain...

Страница 15: ...se 2 2000 Stockerau sterreich Telefon 43 0 2266 604 Telefax 43 0 2266 65311 e mail info austria xyleminc com web www xylemaustria com nderungen auch ohne vorherige Ank ndigung sind Xylem Water Solutio...

Отзывы: