3
OPTIONAL SECONDARY CONTROL MOUNTING
If an additional control station is desired, use control kit number 43670-0004 12 Volt, 18753-0335 24 Volt. Mount secondary control in
same manner as main control.
Mount station selector panel near the main control (flybridge or lower).
1.
Cut a 2” x 1-3/8” (51mm x 35mm) opening for station selector panel within a 1 foot radius of the control.
2.
Route secondary control cable from station selector panel to secondary control location (cable acquired separately – see cable listing).
3.
Insert station selector panel thru mounting hole and attach connectors to mating connectors from controls and searchlight. The connec-
tors marked “flybridge” to go to flybridge control and the connector marked “lower” to lower control. The connector to the nearest control
can be plugged directly into the control. See diagram.
4.
Use bedding compound or sealant to waterproof station selector panel mounting.
5.
Secure panel with self-tapping screws provided.
TROUBLESHOOTING
All lights are thoroughly inspected before shipping and are warranted to operate within specifications. If light does not operate correctly,
CHECK FUSES, AND WIRE HARNESS CONNECTIONS BEFORE PROCEEDING WITH THIS TROUBLESHOOTING.
PROBLEM
SOLUTION
1. Dual filament bulb works in reverse
Reverse orange and gray wires at the bulb terminals
2. Control lever works in reverse in all directions
Power leads to control are reversed
3. Light moves in only three of the possible four
directions
A. Check connectors
B. Replace control
C. If problem persists, return light & control for service
4. Dim light (low voltage)
A. Check voltage at power source
B. Refer to cable listing for proper wire gage and length
5. Bulb operates – no light movement or
light moves – bulb does not operate
Check fuses on front of control