Xylem Goulds AquaBoost Advanced Скачать руководство пользователя страница 32

materials, coatings and other "wear parts" or consumables all of which are not warranted
except as otherwise provided in the quotation or sales form) will be free from defects in
material and workmanship for a period of one (1) year from the date of installation or
eighteen (18) months from the product date code, whichever shall occur first, unless a
longer period is provided by law or is specified in the product documentation (the
“Warranty”).
Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer,
either repair or replace any product which fails to conform with the Warranty provided
Buyer gives written notice to Seller of any defects in material or workmanship within ten
(10) days of the date when any defects or non-conformance are first manifest. Under
either repair or replacement option, Seller shall not be obligated to remove or pay for the
removal of the defective product or install or pay for the installation of the replaced or
repaired product and Buyer shall be responsible for all other costs, including, but not
limited to, service costs, shipping fees and expenses. Seller shall have sole discretion as to
the method or means of repair or replacement. Buyer’s failure to comply with Seller’s
repair or replacement directions shall terminate Seller’s obligations under this Warranty
and render this Warranty void. Any parts repaired or replaced under the Warranty are
warranted only for the balance of the warranty period on the parts that were repaired or
replaced. The Warranty is conditioned on Buyer giving written notice to Seller of any
defects in material or workmanship of warranted goods within ten (10) days of the date
when any defects are first manifest.
Seller shall have no warranty obligations to Buyer with respect to any product or parts of a
product that have been: (a) repaired by third parties other than Seller or without Seller’s
written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or
physical damage; (c) used in a manner contrary to Seller’s instructions for installation,
operation and maintenance; (d) damaged from ordinary wear and tear, corrosion, or
chemical attack; (e) damaged due to abnormal conditions, vibration, failure to properly
prime, or operation without flow; (f) damaged due to a defective power supply or
improper electrical protection; or (g) damaged resulting from the use of accessory
equipment not sold or approved by Seller. In any case of products not manufactured by
Seller, there is no warranty from Seller; however, Seller will extend to Buyer any warranty
received from Seller’s supplier of such products.
THE FOREGOING WARRANTY IS PROVIDED IN PLACE OF ALL OTHER EXPRESS
WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF INSTALLATION OR
EIGHTEEN (18) MONTHS FROM THE PRODUCT DATE CODE , WHICHEVER SHALL
OCCUR FIRST. EXCEPT AS OTHERWISE REQUIRED BY LAW, BUYER’S EXCLUSIVE
REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE
FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT
AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT PAID BY THE BUYER FOR THE
DEFECTIVE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY OTHER FORM
OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL,
CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT
NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE,
LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF
OPPORTUNITY OR LOSS OF REPUTATION.
Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which may
vary from state to state.
To make a warranty claim, check first with the dealer from whom you purchased the
product or visit www.xyleminc.com for the name and location of the nearest dealer
providing warranty service.

9  Product Warranty

30

AquaBoost Advanced Pumping Packages INSTRUCTION MANUAL

Содержание Goulds AquaBoost Advanced

Страница 1: ...INSTRUCTION MANUAL 10 001 326 AquaBoost Advanced Pumping Packages...

Страница 2: ......

Страница 3: ...rams 12 4 1 2 Wiring diagrams 14 4 2 ground earth connections 15 4 3 Pump package location guidelines 16 4 4 Foundation requirements 16 4 5 Level the base on a concrete foundation 16 4 6 Connect the o...

Страница 4: ...ion 26 7 1 5 The pump station does not shut down and no water is used 26 7 1 6 The pump station cycles or hunts erratically 27 8 Other Relevant Documentation or Manuals 28 8 1 Manuals for AquaBoost co...

Страница 5: ...nt or use of parts not provided by Xylem If there is a question regarding the intended use of the equipment please contact a Xylem representative before proceeding Do not change the service applicatio...

Страница 6: ...osal of solid or liquid waste Clean up of spills Exceptional sites CAUTION Radiation Hazard Do NOT send the product to Xylem if it has been exposed to nuclear radiation unless Xylem has been informed...

Страница 7: ...an automatic level control Beware of the starting jerk which can be powerful Rinse the components in water after you disassemble the pump Do not exceed the maximum working pressure of the pump Do not...

Страница 8: ...their components are heavy Failure to properly lift and support this equipment can result in serious physical injury and or equipment damage Lift equipment only at the specifically identified lifting...

Страница 9: ...ve unit and coupling manufacturers for their long term storage procedures For questions about possible long term storage treatment services please contact your local sales and service representative 2...

Страница 10: ...ch is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov 3 1 1 Operational limits Ambient temperature and h...

Страница 11: ...r panel 3 Aquavar IPC controller 4 Temperature relief valve 5 Discharge header stainless steel with grooved connections 6 Suction header stainless steel with grooved connections 7 Pressure transducer...

Страница 12: ...l part numbers start with the following letters Number of pumps Hydraulic HP Voltage Phase AQA 1 simplex A 1ST 15 1 5 HP A 208 230 1 2 duplex B 2ST 20 2 HP B 208 230 3 30 3 HP C 380 3 40 4 HP D 460 3...

Страница 13: ...5 C can be used for the power connections Refer to the input current as listed on the motor nameplate when sizing wire Power supply requirements The power supply required for the AquaBoost unit depend...

Страница 14: ...iminators are used 2 If a bypass line is installed then this valve must be kept closed during normal operation Do not install a check valve 3 Suction gauge recommended 4 Optional tank 5 Discharge gaug...

Страница 15: ...ge gauge 4 Vibration eliminator 5 Anchor the pipe securely if vibration eliminators are used 6 If a bypass line is installed then this valve must be kept closed during normal operation Do not install...

Страница 16: ...N C COM P MD GV WD WV GM WM VFD MODEL HP FLA MCA DISC GROUND WIRE VFD INCOMING WIRE VFD WIRE GROUND WIRE MOTOR MOTOR WIRE MODEL FRAME 208V 230V 1 1QB15A 1 1 2 11 10 13 8 12 5 30A 12 AWG 14 AWG 14 AWG...

Страница 17: ...AWG 14 AWG 14 AWG 14 AWG AVA20015A0F0D0X1 A2 2QB20B 2 15 13 6 16 9 15 3 AVA20020A0F0D0X1 2QB30B 3 21 2 19 2 23 9 21 6 12 AWG 6 AWG AVA20030A0F0D0X1 2QB50B 5 33 4 30 4 37 6 34 2 60A 10 AWG 4 AWG 12 AW...

Страница 18: ...f nothing else is specified Do not install and operate the equipment in closed systems unless the system is constructed with properly sized safety and control devices Acceptable devices Pressure relie...

Страница 19: ...ation then connect the tank to the discharge manifold as shown 1 2 1 Storage tank 2 Discharge gauge 3 Precharge the tank according to the tank specific IOM 4 7 Connect the optional low suction pressur...

Страница 20: ...re that the flange bolts are adequately torqued NOTICE Never force piping to make a connection with a pump Check Explanation comment Checked Check that the suction and discharge pipes are supported in...

Страница 21: ...hich optional vibration eliminators are connected is properly anchored to the floor This is necessary for maximum effectiveness Fastening WARNING Only use fasteners of the proper size and material Rep...

Страница 22: ...then warm up the pump prior to operation Circulate a small amount of fluid through the pump until the casing temperature is within 100 F 38 C of the fluid temperature At initial startup do not adjust...

Страница 23: ...m requirements Low suction pressure switch optional WARNING Always disconnect and lock out power to the package and the driver before you perform any installation or maintenance tasks Failure to disco...

Страница 24: ...ts automatically and pump speed continues to ramp up until the system pressure satisfies the set point The system pressure rises above the set point The pump automatically reduces speed until the syst...

Страница 25: ...is not all over the inside of the motor and in the bottom of the motor This could be a sign of overfilling Refer to the lubrication instructions from the motor manufacturer Close coupled pumps For a h...

Страница 26: ...r breakers are tripped Check power fuses and breakers Breakers are shipped in the OFF position Replace blown fuses The pump station is not properly grounded earthed Check that proper grounding earthin...

Страница 27: ...rter coil and the neutral white wire 120 volts should be measured If no voltage is measured then check incoming power and fuses If voltage is measured then go to the next step 4 With the HOA still in...

Страница 28: ...pair facility 7 1 4 The pump station experiences excessive vibration Cause Remedy The motor pump or piping is loose Make sure that all fasteners and components are properly tightened Pump station vibr...

Страница 29: ...s erratically Cause Remedy The pumps are oversized for the current demand Check the application Possibly increase the size of the bladder tank for low demand situations The inlet pressure is fluctuati...

Страница 30: ...llation operation and maintenance of your AquaBoost Pumping System can be found in the IOMs provided for the associated equipment Equipment Manual Goulds Pumps Model NPE IM013R10 Aquavar IPC IM318 REV...

Страница 31: ...replaced Seller shall have no warranty obligations to Buyer with respect to any product or parts of a product that have been a repaired by third parties other than Seller or without Seller s written a...

Страница 32: ...contrary to Seller s instructions for installation operation and maintenance d damaged from ordinary wear and tear corrosion or chemical attack e damaged due to abnormal conditions vibration failure...

Страница 33: ...ent running on their premises including model name software version and how devices are connected to each other and the local network Xylem recommends creating and maintaining offline copies of config...

Страница 34: ......

Страница 35: ......

Страница 36: ...solutions for water electric and gas utilities In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands a...

Отзывы: