4.2.7 Coupler limitations
Brand
Suitable for
variable speed
application
Minimum
recommended
speed
Allowable installation misalignment limits
Y Dimension
(inch)
Maximum
temperature
Minimum
temperature
Coupler size Parallel (inch) Angular (inch
or degree)
TB Wood’s
Sure-Flex
(Neoprene
sleeve)
Yes
50% of full
speed
3
0.010
0.035
1.188
200°F
–0°F
4
0.010
0.043
1.500
5
0.015
0.056
1.938
6
0.015
0.070
2.375
7
0.020
0.081
2.563
8
0.020
0.094
2.938
9
0.025
0.109
3.500
10
0.025
0.128
4.063
11
0.032
0.151
4.875
12
0.032
0.175
4.688
13
0.040
0.195
6.688
14
0.045
0.242
7.750
TB Wood’s
Sure-Flex
(Hytrel Sleeve)
No
N/A
3
—
—
—
250°F
–65°F
4
—
—
—
5
—
—
—
6
0.010
0.016
2.375
7
0.012
0.020
2.563
8
0.015
0.025
2.938
9
0.017
0.028
3.500
10
0.020
0.032
4.063
11
0.022
0.037
4.875
12
0.025
0.042
5.688
13
0.030
0.050
6.625
14
0.035
0.060
7.750
4.3 Piping checklists
4.3.1 Piping checklist
WARNING:
• The heating of water and other fluids causes volumetric expansion. The associated
forces can cause the failure of system components and the release of high-
temperature fluids. In order to prevent this, install properly sized and located
compression tanks and pressure-relief valves. Failure to follow these instructions can
result in serious personal injury or death, or property damage.
• Avoid serious personal injury and property damage. Make sure that the flange bolts
are adequately torqued.
• Never force piping to make a connection with a pump.
4 Installation
20
G&L Pumps Series A-C 8100 Base Mounted Centrifugal Pump INSTRUCTION MANUAL