Position number
Description
Color
Indication
3
Pump status
Constant green
Automatic mode
• The pump operates.
Hand mode
• The pump operates.
Flashing green
The pump is on standby.
–
The pump does not
operate.
4
Alarm
Red
There is a class A alarm.
Yellow
There is a class B alarm.
–
There is no alarm.
Table 2: Buttons
Position number
Function
5
Acknowledgement of an alarm
6
Navigation in the menus
7
Selection of the automatic mode
8
Selection of the off mode
9
Selection of the hand mode
10
Confirmation
8.2 Alarms
Active alarms
The Active alarms menu lists all the active alarms. When an alarm is selected, the following
information shows:
• Status
• Date and time
• Priority level
Alarm history
The Alarm history menu lists the alarm history. When an alarm is selected, more information
shows:
• Event
• Date and time
• Priority level
8.3 Information
8.3.1 Pump information
Running data
Part
Description
Total starts
The total number of pump starts
Total run time
The total run time of the pump
Current
The input current of the motor
Voltage
The input voltage of the motor
Power
The input power of the motor
Temperature
Applicable for Pt100 sensor
The temperature measured by the Pt100 sensor