7.6 The pump delivers too little or no water
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and lock out power before servicing
to prevent unexpected startup. Failure to do so could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in
equipment damage.
Cause
Remedy
The impeller rotates in the wrong
direction.
See
on page 57.
One or more of the valves are set
in the wrong positions.
• Reset the valves that are set in the wrong position.
• Replace the valves, if necessary.
• Check that all valves are correctly installed according to media
flow.
• Check that all valves open correctly.
The impeller is difficult to rotate
by hand.
• Clean the impeller.
• Clean out the sump.
• Check the clearance between the propeller and the pump
housing.
The pipes are obstructed.
Clean out the pipes to ensure a free flow.
The pipes and joints leak.
Find the leaks and seal them.
There are signs of wear on the
impeller, pump, and casing.
Replace the worn parts.
The liquid level is too low.
• Check that the level sensor is set correctly.
• Depending on the installation type, add a means for priming the
pump, such as a foot valve.
Always state the serial number of the product, see
on page 12.