Position Part
Description
11
Stator
Equipped with temperature sensors in windings
12
Electrical lead-
through unit
13
Cable entry
14
Lifting handle
15
Guide vanes
Spare part requirements
The following applies when servicing or repairing the pump:
• Modifications to the unit or installation should only be carried out after consulting with
Xylem.
• Original spare parts and accessories that are authorized by Xylem are essential for
compliance. The use of other parts can invalidate any claims for warranty or
compensation. For more information, please contact your local sales and service
representative.
3.4 Monitoring equipment
The following monitoring systems can be used:
• MiniCAS II
• MAS 801
• MAS 711
MiniCAS II This is the most-basic alternative. MiniCAS II can protect the pump against the
following:
• Over-temperature in the stator windings
• Leakage in the inspection chamber
MAS 711 This is a more advanced system, and is used when more monitoring channels
are required.MAS 711 requires a separate signal cable, with 12 or 24 leads.
MAS 801 This is the most advanced monitoring system. With the MAS 801, the analog
signals from the sensor are converted to digital signals inside the pump. The
digitalized monitoring signals are transmitted using the control cores in the
SUBCAB
™
power cables. This allows a broad range of sensor signals, and
eliminates the need for a separate signal cable.
Ex-proof pumps
Ex-proof pumps must have the thermal contacts or the thermistors connected to the control
panel.
The sensors must be connected to either of the Flygt monitoring relays or an equivalent.
General
• The monitoring equipment must be of a design that prevents automatic restart.
• Information in the junction box of the pump indicates whether the pump is equipped with
optional sensors.
3.5 The MAS 801 monitoring equipment
3.5.1 MAS 801
With the MAS 801, one control unit can be used for several pumps, up to a maximum ten
pumps.
Each pump has a built-in PEM and has its own base unit.
3 Product Description
14
P7030, P7035, P7040 Installation, Operation, and Maintenance Manual