Alarm source
Action
FLS10
1. Drain the fluid in the inspection chamber.
2. Check the oil level. Fill with new oil if necessary.
Check the inspection chamber again after one week of operation.
If leakage has occurred, then do the following:
1. Drain the fluid.
2. Change the mechanical seal unit.
3. Replace the oil with new oil.
The thermistor/thermal contact Check the start and stop levels.
The overload protection
Check that the propeller can rotate freely.