Installation
Install the pump
These requirements apply:
• Use the pump dimensional drawing in order to ensure proper installation.
• In S-, T-, and Z-installations the pump must be equipped with cooling jacket
• Provide a suitable barrier around the work area, for example, a guard rail.
• Check the explosion risk before you weld or use electric hand tools.
• Remove all debris from the inlet piping system before you install the pump.
WARNING:
• Before installing the pump, check that the cable and cable entry have not been
damaged during transportation.
• Note that special rules apply to installation in explosive atmospheres.
• Make sure that the pump cannot roll or fall over and injure people or damage property.
• Do not install CSA-approved products in locations that are classified as hazardous in the
national electric code, ANSI/NFPA 70-2005.
NOTICE:
• Do not run the pump dry.
• Never force piping to make a connection with a pump.
Install with P-installation
In the P-installation, the pump is installed on a stationary discharge connection, and
operates either completely or partially submerged in the pumped liquid. These
requirements and instructions only apply when the installation is made according to the
dimensional drawing.
Figure 4: P-installation
Installation
Flygt 3201 Installation, Operation, and Maintenance Manual
17