Labels are attached to the SUBCAB cable which is used for communication when there is
more than one SUBCAB cable. This section gives instructions for identifying which cable is
used for communication, when the label is missing.
A multimeter can be used to identify the following:
• Which signal leads are connected to the PEM
• For explosion-proof pumps: which leads are connected to the thermal contacts or
thermistors
Unused leads in the pump are isolated.
4.5.6.1 Measure the resistance
At the PEM, T1 is + and T2 is −.
1. Select a SUBCAB cable.
2. Use a multimeter to measure the resistance across T1–T2.
Measure both polarities.
T1–T2 resistance
T1–T2 resistance
Opposite polarity
Conclusion
70–130 kilohms
∞ ohm
The PEM is connected to this
cable.
∞ ohm: infinite resistance
∞ ohm
The PEM is not connected to
this cable.
3. Ex-proof pumps only: Use a multimeter to measure the resistance across T3–T4.
T3–T4 resistance
Stator temperature sensors
∞ ohm
The T3–T4 signal leads of this cable are not
used.
0–5 ohm
Thermal contacts are connected to this cable.
150–300 ohm
Thermistors are connected to this cable.
4. Repeat this process on the other cables until the signal leads which are used for
communication, have been identified.
4.5.7 Prepare the SUBCAB
™
cables
This section applies to SUBCAB
™
cables with twisted-pair control conductors.
4 Installation
34
P7900 Installation, Operation, and Maintenance Manual
Содержание FLYFT P7900
Страница 1: ...Installation Operation and Maintenance Manual 90028101_1 0 P7900...
Страница 2: ......