Parameter Monitored
Sensor
Signal Cable,
Number of
Leads Required
Standard or
Optional
Leakage in the stator housing or
inspection chamber
Float switch leakage sensor
(FLS)
12
Standard
Water in oil: standard drive units
only. (Not applicable for drive
units with internal closed-loop
cooling.)
Capacitive leakage sensor (CLS) 24
Optional
Support bearing temperature
Pt100 analog temperature sensor 24
Optional
Pump memory
Printed circuit board for pump
memory includes a temperature
sensor.
12
Standard
Pump current
A current transformer in the control cabinet is required.
Power monitoring
Separate electronic instrument using three current
transformers.
Optional
For more information on the stator temperature monitoring, see
on page 15.
3.5.1 FLS: float switch sensor
The float switches are leakage sensors.
The float switches are located in the lower part of the stator housing and in the junction box.
3.5.2 Vibration sensor (VIS10)
Description
Measured value
Fault values
The vibration sensor located in
the junction box measures
vibrations in one direction. The
output is a 4-20 mA signal
proportional to the vibration
level.
Current, 4-20 mA
• >> 20 mA indicates a short circuit.
• << 4 mA indicates a fault.
• A zero value indicates a broken wire or bad
contact in a connector.
3.5.3 Bearing temperature measurement
Pt100 sensors monitor the bearing temperatures to protect the pump from the consequences
of a bearing failure.
Main bearing
Main bearing temperature monitoring is standard in the MAS 711 and MAS 801. The Pt100
sensor is pressed by a spring against the outer ring of the ball bearing.
Support bearing
Support bearing temperature monitoring is an option in the MAS 711 and MAS 801. The
Pt100 sensor is pressed by a spring against the outer ring of the roller bearing.
Alarms
Two adjustable alarm limits can be used:
• Early warning: “B”-alarm
• Pump stop: “A”-alarm
3.5.4 Stator temperature monitoring methods
The purpose of stator winding temperature monitoring is to make the motor shut off at high
temperature. There are several monitoring methods, depending on the voltage of the motor,
and types of thermal sensors chosen.
By using an analogue sensor, two adjustable alarm limits can be used, one for warning (“B”-
alarm) and one for pump stop (“A”-alarm). The configurations which can be used for
3 Product Description
P7900 Installation, Operation, and Maintenance Manual
15