en – Original Instructions
e-IXP, e-IXPC, e-IXPF series – Additional Installation, Operation and Maintenance Instructions
21
4.5
Optimyze
TM
connection
The figure shows the connections for installing the optimyze
TM
monitoring device (accessory).
See the optimyze
TM
Quick Start Guide for more information.
1.
optimyze
2.
Vibration sensor V2
3.
Temperature sensor T1
4.
Vibration sensor V4
5.
Temperature sensor T1
6.
Vibration sensor V1
7.
Vibration sensor V3
4.6
Electrical connection
4.6.1
Precautions
Electrical measures
DANGER: Electrical hazard
Before starting work, check that the electric power supply is disconnected and locked out, to
avoid unintentional restart of the unit, the control panel and the auxiliary control circuit.
NOTE:
Only use dynamically balanced motors with half-sized key at the shaft end (IEC 60034-14), and
with normal vibration rate (N).
NOTE:
Only use single-phase or three-phase motors with sizes and powers in compliance with
European standards.
NOTE:
The mains voltage and frequency must match the specifications on the data plates.
Ground
DANGER: Electrical hazard
Always connect the external protection conductor (ground) to the ground terminal before
attempting to make any other electrical connections.
XI
P_M0
00
9_A_sc
2
1
5
4
6
7
3