![Xylem e-IXP Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/xylem/e-ixp/e-ixp_additional-installation-operation-and-maintenance-instructions_4222050020.webp)
en – Original Instructions
20
e-IXP, e-IXPC, e-IXPF series – Additional Installation, Operation and Maintenance Instructions
NOTE:
The radial and axial deviations between the half couplings must not exceed the values
indicated by the manufacturer. Refer to the motor-pump coupling instruction manuals for
more information.
The figure shows the correct alignment of the coupling.
4.4.3
Installing the protections
1.
Top fastener
2.
Top coupling protection
3.
Bottom fastener
4.
Side fasteners
5.
Bottom coupling protection
6.
Adjustment ring
7.
Bearing cover
8.
Coupling
9.
Motor
1.
Reinstall the bottom protection by screwing the bottom fastener.
2.
Insert the ring with the slot facing down and press it against the motor in the axial direction.
3.
Reinstall the top protection and screw the top and side fasteners.
XIP_M0011_A_sc
XIP_M0012_A_sc
2
1
4
3
5
6
7
8
9