background image

Warranty 

Ai1 products are warranted for twelve (12) months subject to this limited warranty 

Limited Warranty: Ai1 products are warranted to be free from defects in materials and workmanship under normal 
use and service for twelve months from the date of shipment unless otherwise specified.  Batteries, desiccant, and 
other consumables have no warranty. The Manufacturers obligation under this warranty is limited to repairing or 
replacing (at the Manufacturers option) defective Products, which shall be the sole and exclusive remedy under this 
warranty. Products may not be returned without prior authorization.  The Customer assumes all costs of removing, 
reinstalling, and shipping Products to The Manufacturer. For all returns, The Customer must fill out a "Statement of 
Product Cleanliness and Decontamination" form and comply with the requirements specified in it. The Manufacturer 
reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety 
concerns.  The Manufacturer will return such Products by surface carrier prepaid within Australia. To all other 
locations, The Manufacturer will return such Products best way CIP (port of entry) per Incoterms ® 2010. This 
warranty shall not apply to any Products which have been subjected to modification, misuse, neglect, improper 
service, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or 
implied. The warranty for services performed by The Manufacturer such as programming to Customer specifications 
or product specific training, is part of The Manufacturers product warranty.   Ai1 products are intended to be part of 
a well maintained and comprehensive monitoring system. Reliable operation depends on suitable site selection, 
correct installation, real time monitoring of data, adequate maintenance and investigation of alarm and diagnostic 
information. Stations are designed to be mounted above water, submersion may result in damage. All ownership 
and risk transfers to the purchaser at the time of shipment. The Manufacturer does not accept any liability or 
consequential damages for any failure of systems supplied.  Repair or service of the system is only to be handled by 
factory trained technicians. No service by The Customer is allowed.  Refer to terms and conditions of sale for full 
details.  THE MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The Manufacturer hereby disclaims, to the fullest 
extent allowed by applicable law, any and all warranties and conditions with respect to the Products, whether 
express, implied or statutory, other than those expressly provided herein. 

Precautions 

DANGER 

 MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR 

NEAR ROADS, RIVERS, WATER BODIES, ELEVATED PLATFORMS, REMOTE LOCATIONS AND OTHER SIMILAR HAZARDS.  
You are responsible for conformance with governing codes and regulations, including safety regulations, and the 
integrity and location of sites. Installation sites should be evaluated and approved by a qualified engineer. Prior to 
performing site or installation work, obtain required approvals and permits. Comply with all governing permits and 
use only qualified personnel. The use of licensed and qualified contractors is highly recommended. Read all 
applicable instructions carefully and understand procedures thoroughly before beginning work. Wear all relevant 
personal protective equipment, including a hardhat and eye protection, and take other appropriate safety 
precautions while working.  You can be killed or sustain serious bodily injury if the system you are installing, 
constructing, using, or maintaining, or a tool, stake, or anchor, come in contact with overhead or underground utility 
lines.  Prior to performing site or installation work, inform all utility companies and have all underground utilities 
marked. Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a 
licensed and qualified electrician. Protect all equipment from over-voltage, water and electrostatic discharge.  Do 
not perform any work in inclement weather, including wind, rain, snow, lightning, etc. Periodically (at least yearly) 
check for wear and damage, including corrosion, stress cracks, frayed cables, loose clamps, fastener tightness, 
electrical ground connections, etc. and take necessary corrective actions. While every attempt is made to embody 
the highest degree of safety in all Measurement Science products, the customer assumes all risk from any injury 
resulting from improper installation, use or maintenance of these products.  The Manufacturer recommends a level 
of calibration appropriate to the application, and recommends, at a minimum, recalibration every three years 

Measurement Science products including the Ai1 and SDI12 sensors are distributed 
globally by Xylem Analytics.  Please contact your local distributor for support services. 

 

Содержание Ai1 Series

Страница 1: ...Ai1 All in one rugged remote monitoring measci com ai1 Quick Start Guide October 2019 Revision...

Страница 2: ...CLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The Manufacturer hereby disclaims to the fullest extent allowed by applicable law any and all warranties and condit...

Страница 3: ...tom mounted sensors 16 5 2 1 Sensor plate 16 5 2 2 Panel mounted connectors 17 5 2 3 Customizable Gland Plate 17 5 2 4 Magnetic mounting feet 17 5 2 5 Side Cable Entry 18 5 3 Pole Mounting Kit 18 6 Po...

Страница 4: ...16 1 1 Power related issues 32 16 1 1 Software and diagnostics 32 17 Sending a new program 36 18 Declarations 38 18 1 For models including LaserLEVEL 38 18 1 1 Warning 38 18 1 2 Caution 38...

Страница 5: ...ion can be selected as the primary communications method or added to any other communications system as a backup method The Iridium module is a separate component designed to mount on top of the Ai1 T...

Страница 6: ...s Housing Both the top and bottom plates may be opened to access in internal components Fully unscrew the 6 screws holding the lid in position to open Both top and bottom plates have an o ring seal an...

Страница 7: ...s a dedicated regulator a step up regulator to increase the voltage from the 3 7V lithium ion battery to operate from 12V The normal range for the regulator voltage is 12V 0 5V while the normal voltag...

Страница 8: ...al plate is as shown below Figure 7 Terminal Plate Schematic 4 2 1 USB Port It is possible to power the Ai1 using the USB port to allow easy configuration program and firmware uploads and basic operat...

Страница 9: ...ain operational although communications will stop The switch is inline with an internal fuse that is accessed by opening the Ai1 electronics housing as described in 4 1 By default stations are shipped...

Страница 10: ...itation ports limited to 2 5V rather than 5V Switched 12V will not operate Single flash every 15 seconds Operating on battery solar power Full system functionality Always on Program stopped or no prog...

Страница 11: ...s running from a 3 7V Lithium Ion battery this provides the full 5 to 20V range of regulation For externally powered systems running from 12V this reduces the range to approximately 12 5 to 20V The ou...

Страница 12: ...riggers for immediate program reaction May be used as digital output with extremely limited drive 0 1mA 3V A2 Analog Input 2 As with A1 A3 Analog Input 3 As with A1 and A2 but cannot be used for curre...

Страница 13: ...l wired to A3 Similarly the relay connected to A4 has its own common terminal wired to A4 and the normally open terminal to A4 While the relay is rated to 8A the contacts should only be used for up to...

Страница 14: ...nnected to Com1 depending on the P_SW state TX_3 RX_3 Miscellaneous EXO SOA The electronics housing may include an EXO Signal Output Adapter SOA to convert the proprietary EXO signal to an SDI12 outpu...

Страница 15: ...ounted systems such as the USB port and integrated bubble level for stations requiring levelling Incorrect level may significantly degrade instrument range and measurement accuracy for non contact sen...

Страница 16: ...olid for customization to suit the project The bottom plate includes 4 x 6mm holes to suit M6 bolts on the same 100 x 100mm square as the top mounting plate Figure 14 6mm holes for M6 bolts The 100mm...

Страница 17: ...ting of the station to expose the instrument tube through the centre of the buoy The sensor is connected with a Subcon panel mount connector to allow quick disconnect without allowing water ingress or...

Страница 18: ...A pole mounting kit suits a wide variety of vertical poles up to 110mm in diameter The kit includes two stainless steel clamps on the body of the Ai1 a pair of brackets and a pair of suitably sized st...

Страница 19: ...ough the full 180 Adjust the rotate and tilt screws to set the desired fixed monitoring direction It is recommended to make sure that the lens is pointing down to minimize fouling 7 Power Budget Solar...

Страница 20: ...External power Maximum power conservation 1 0 1 9 Ai1 36W 4x9W 12Ah VR SLA May require communications window and slow measurement updates 2 0 2 9 Ai1 18W 2x9W 8Ah LiPo 3 0 3 9 Ample power full time o...

Страница 21: ...perpendicular incoming energy With fixed installations winter sunshine is maximised by orientating the panel South in the Northern hemisphere or North in the Southern hemisphere For a station install...

Страница 22: ...valent 4 x 9W 36W total 9W equivalent 9W equivalent Table 4 Recommended Panel Size Equivalents 8 Communications Ai1 products come in WIFI CELLULAR and RADIO options If you are unsure of the model prov...

Страница 23: ...edited as required If you do this you will also need to download a copy of the Ai1OS library file to the same folder that you do your editing for the local compiler to work either from the datalogger...

Страница 24: ...on The Ai1 is optimised for automatic connection to Eagle io At the top of the CRBasic include the definition of DESTINATION as shown below The Ai1 will automatically establish the connection to Eagle...

Страница 25: ...TCP Callback use existing and use the IMEI number from the datalogger The station will automatically configure the data tables and upload data to Eagle io For any other eagle io functions refer to th...

Страница 26: ...ion damage including heat pump effects that may occur with small leaks in high humidity environments As the daytime temperature increases warm humid air may be drawn in which condenses to water in coo...

Страница 27: ...he 2x17 header pins may be bent Fully remove the middle spacer on the bottom of the center assembly Unscrew both ends and completely remove Loosen slightly the remaining spacers to allow the battery t...

Страница 28: ...Micro B cables USB to serial RS23 adapter 6mm socket extension socket Drill set 1 0 to 6 0mm Battery Drill Multimeter Heat shrink and heat shrink gun Side cutters Wire strippers Soldering iron gas rec...

Страница 29: ...f precision a representation of the measurement uncertainty For a full definition https gisgeography com gps accuracy hdop pdop gdop multipath GPS_Height The estimated height of the location Refer to...

Страница 30: ...LatA 100 Calculate the degrees part minutesCalc LatA 100 degreesCalc 60 Calculate the minutes part NUMBER lat currentValue degreesCalc minutesCalc sign Combine if LongB 0 sign 1 else sign 1 degreesCa...

Страница 31: ...d is likely damaged Open the cannister and measure the battery voltage directly If the voltage is low request a replacement battery spare part otherwise look for secure connections f If all above step...

Страница 32: ...evice is connected or disconnected when connecting through USB This may indicate power problems datalogger resets or remote program changes If the datalogger fails to connect yet gives the USB connect...

Страница 33: ...te the cellular firmware version over the air To check the current version use the command SHOW CELLULAR INFO Figure 22 Checking cellular firmware information As can be seen here the reported firmware...

Страница 34: ...is active Figure 25 Serial talk through to communicate directly with serial sensors o SDI12 Similar to serial talk through but customised for SDI12 communications The screenshot below shows a sample...

Страница 35: ...ta until complete SDI12 terminal mode can operate in parallel to datalogger issued SDI12 commands however SDI12 Failed or SDI12 Busy may be returned if the datalogger is performing another program ope...

Страница 36: ...t Properties Selection the Connection tab and click Remote access to enable remote access By default Eagle io will allow access for 1 hour limited to your specific IP address If you want longer or fro...

Страница 37: ...e the Send button to send the appropriate file The file must be a unique name from the currently running file Do not use the Stop button or the connection to Eagle may be lost and a site visit may be...

Страница 38: ...this device with a modified housing or optics that exposes the laser source may result in direct exposure to laser radiation and the risk of permanent eye damage Removal or modification of the diffus...

Страница 39: ...and diagnostic information Stations are designed to be mounted above maximum flood elevation flooding may result in damage In order to protect the design information purchasers warrant to not reverse...