background image

5019T Flat Panel Industrial Touch Monitor                                                                  Chapter 5 – Hardware 

 

29 

143627(A)

 

DVI-D Input Connector 

The DVI-D Input Connector is a D-sub connector with 26 pins (P3). 

Table 5-2. DVI-D Input Connector Pinout 

Pin 

Signal Name 

Pin 

Signal Name 

TMDS Data 2- 

TMDS Data 2+ 

Digital ground 

 NC 

NC 

DDC Clock 

DDC Data 

Analog Vertial Sync 

TMDS Data 1- 

10 

TMDS Data 1+ 

11 

Digital ground 

12 

NC 

13 

NC 

14 

+5V power supply for 

DDC (optional) 

15 

Ground (+5, 

Analog H/V Sync) 

16 

NC 

17 

TMDS Data 0- 

18 

TMDS Data 0+ 

19 

Digital ground 

20 

NC 

21 

NC 

22 

Digital ground 

23 

TMDS Clock + 

24 

TMDS Clock- 

25 

NC 

26 

NC 

NC stands for No Connection 

 

Composite Video and S-Video Input 

The S-Video input (J1) is a min-din 4-way. The Composite Video input (j3) is 

through an RCA jack (yellow). 

Serial Interface 

The serial interface is an RS-232C. The specifications are as follows: 

Data Transmission Speed:  9600 bps 

Data Length:  8 bits 

Stop Bit:  1 bit 

Parity:  None 

Содержание 5019T

Страница 1: ...2004 XYCOM AUTOMATION INC Printed in the United States of America 5019T Flat Panel Industrial Touch Monitor User Manual...

Страница 2: ...o communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense...

Страница 3: ...0 ON SCREEN DISPLAY OSD SWITCH 20 MODE AND IMAGE ADJUSTMENT 20 Reset Factory Default Settings 25 ANALOG RGB INTERFACE SPECIFICATIONS 25 VIDEO MODES 25 CHAPTER 4 OPERATOR INPUT 26 INSTALLING THE TOUCH...

Страница 4: ...85 mounting depth Five wire analog resistive touch screen with either RS 232 or USB interfaces Front panel controls for on screen menus with lock out switch on rear of units for units with aluminum b...

Страница 5: ...Feature Description Menu This button is used to open and select options in the On Screen Display OSD menu Up This button moves the selector up on the menu or adjustment bar Down This button moves the...

Страница 6: ...do not order the touch option neither touch output option will be available Touch Out USB Touch screen output on USB models Touch Out RS 232 Touch screen output on RS 232 models OSD Selector Switch Us...

Страница 7: ...t and disconnect the power cord before making any adjustments to the inside or outside of the monitor Warning For Hazardous Locations installation review Hazardous Locations Installation in Chapter 2...

Страница 8: ...sure to account for the unit s depth when choosing the depth of the enclosure 2 Create a cutout in the enclosure see Figure 2 2 3 Be sure to place the unit at a comfortable working level 4 Make sure t...

Страница 9: ...onductive particles and other harmful contaminants from entering the enclosure Do not select a location near equipment that generates excessive electromagnetic interference EMI or radio frequency inte...

Страница 10: ...5019T Flat Panel Industrial Touch Monitor Chapter 2 Installation 8 143627 A Product Dimensions 5019T Dimensions Figure 2 1 5019T Dimensions Note All dimensions are in inches...

Страница 11: ...nd types of conductors color codes and connections necessary for safe grounding of electrical components The code specifies that a grounding path must be permanent no solder continuous and able to saf...

Страница 12: ...wire or greater for the 5019T s power cable Isolate the AC main circuit line I O signal lines and power cord do not bind or group them together Excessive Heat To keep the temperature in range the coo...

Страница 13: ...e Provincial and local electric codes which provide data such as the size and types of conductors color codes and connections necessary for safe grounding of electrical components It is recommended th...

Страница 14: ...y devices attached to this equipment in Division 1 locations It is the responsibility of the customer to ensure that the product is properly rated for the location If the intended location does not pr...

Страница 15: ...Class and Division explanations are derived from Article 500 Sections 5 and 6 of the United States National Fire Protection Agency National Electric Code NFPA 70 1990 They are not complete and are in...

Страница 16: ...osures Division 2 Locations Class I volatile flammable liquids or flammable gasses are handled processed or used but confined within closed containers or closed systems from which they can escape only...

Страница 17: ...ations require that a power switch rated for ordinary locations may be used if it is located in an area specified as non hazardous However limits in cable length between the workstation and the power...

Страница 18: ...e operator in the course of normal operation Warning To maintain a safe condition never use an external keyboard or mouse or USB port devices when the unit is operating in a hazardous environment Alwa...

Страница 19: ...22 2 No 142 Information Technology Equipment EN 60950 Information Technology Equipment Mounting Options The 5019T can be mounted in a panel or to an arm The following sections describe the two mountin...

Страница 20: ...install the mounting clips see Figure 2 3 for mounting clip locations Tighten the clips in a crisscross pattern This will help to develop an even pressure on the sealing gasket Tighten the clips unti...

Страница 21: ...imensions for arm mounting Please note that there are 3 sets of mounting holes on the back of the 5019T monitor one for mounting the monitor on a 100 mm VESA arm one for attaching a Xycom Automation 1...

Страница 22: ...ng the OSD switch to enable Caution Please use the OSD after confirming the position of the OSD Select Switch Touch data is transmitted to host while OSD menu is displayed Mode and Image Adjustment No...

Страница 23: ...tion Picture in Picture Video Scaling Language Video Source Utilities Volume Exit Press MENU to select the highlighted adjustment menu the first adjustment option in the menu will be highlighted Use U...

Страница 24: ...e Exit menu Press or to exit the OSD adjustment menus See Figure 3 2 through Figure 3 7 for snapshots of the adjustment menus and their respective adjustment options Figure 3 2 OSD Adjustment Menus Br...

Страница 25: ...Panel Industrial Touch Monitor Chapter 3 Monitor Settings 23 143627 A Figure 3 4 OSD Adjustment Menus Picture in Picture Video Scaling Figure 3 5 OSD Adjustment Menus Graphic Scaling Modes Language Vi...

Страница 26: ...5019T Flat Panel Industrial Touch Monitor Chapter 3 Monitor Settings 24 143627 A Figure 3 6 OSD Adjustment Menus Utilities Figure 3 7 OSD Adjustment Menus Volume Exit Menu...

Страница 27: ...the following Based on VESA standard separate analog RGB 0 7Vp p positive true typically Input range 0 5 to 1 0Vp p typical with terminal resistance of 75 H sync signal input TTL level negative true...

Страница 28: ...he Elo Touch driver 5 After driver installation is complete the computer must be restarted After restart the 4 point calibration will automatically run The touch screen drivers are located on the Docu...

Страница 29: ...ry tap of the touch screen is interpreted as a left button To display the icon bring up the Elo touch controller applet START SETTINGS CONTROL PANEL ELO Check the Display right mouse button box under...

Страница 30: ...Input Connector The VGA input connector is a D sub connector with 15 pins Table 5 1 VGA Input Connector Pinout Pin Signal Name 1 Red 2 Green 3 Blue 4 Reserved GND 5 GND Digital 6 GND Red return 7 GND...

Страница 31: ...Data 1 11 Digital ground 12 NC 13 NC 14 5V power supply for DDC optional 15 Ground 5 Analog H V Sync 16 NC 17 TMDS Data 0 18 TMDS Data 0 19 Digital ground 20 NC 21 NC 22 Digital ground 23 TMDS Clock 2...

Страница 32: ...Carrier Detect 2 RX Receive Data 3 TX Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS Clear To Send 9 NC No connection Note Since all serial inte...

Страница 33: ...fication Mechanical Height Width Depth Mounting Depth Weight 15 70 398 78 mm 18 51 470 15mm 3 00 76 2 mm 2 85 72 39 mm 21 lbs 9 52 kg Electrical AC Power DC Power 100 240 V AC 1A 50 60 Hz 18 30 V DC 2...

Страница 34: ...rating 0 to 50 C 32 to 122 F 20 to 60 C 4 to 140 F Humidity Operating Non operating 20 to 80 RH non condensing 20 to 80 RH non condensing Vibration 5 2000 Hz Operating Non operating 0 006 0 15 mm peak...

Страница 35: ...ing of system error messages encountered 4 Any relevant output listing from the Microsoft Diagnostic utility MSD or other diagnostic applications 5 Details of attempts made to rectify the problem s an...

Страница 36: ...it by calling Xycom Automation Inc at 734 429 4971 2 Please have the following information Company name shipping and billing address Type of service desired Product repair Product exchange Product mod...

Страница 37: ...nel 3 Interface Specifications Analog RGB 24 Line Voltage Variation 10 Mounting Clips 17 Mounting Dimensions Panel Cutout 16 Mounting Dimensions VESA Arm 18 Mounting Options 16 OSD Switch 19 Pinout DV...

Страница 38: ...143627 A Xycom Automation Inc 734 429 4971 Fax 734 429 1010 http www xycom com Canada Sales 905 607 3400 Northern Europe Sales 44 1604 790 767 Southern Europe Sales 39 011 770 53 11...

Отзывы: