: Observe all governing building codes and city ordinances.     

                  A 120 volt, 60 Hz., AC, 15-amp outlet is needed (fused electrical circuit is required) 

It is the customer’s responsibility:   

To contact a qualified electrical installer, to assure that the electrical installation is adequate and in conformance with 

National Electrical Code, ANSI/ NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91 - latest edition and 
all local codes and ordinances.   

 
 
 

 
 
 
 
 
 
 

 

2. HEIGHT & CLEARANCE 

3. VENTING REQUIREMENTS 

        IMPORTANT: 

 

NEVER exhaust air or terminate ductwork into crawl spaces, between walls, ceiling, attics or garages.   

All exhaust 

must be ducted to the outside. 

 

Hood mounted too low could result in heat and/or fire hazard. Hoods mounted too high will be hard to reach and will lose 

its performance and efficiency.   

 

Use metal ductwork only.

 

 

DO NOT use plastic ventilation.   

 

DO NOT use 4” (10.2 cm) laundry-type wall caps. 

 

Fasten all connections with sheet metal screws.    Tape all joints with aluminum tape.   

 

Use caulking to seal exterior wall or roof openings around the cap.   

 

The ventilation system must have a damper. If the roof or wall cap has a damper, you may opt out from usage of your 

range hood supplied damper (for some models only). 

        For the most efficient & quiet operation:   

 

A distance of 26” to 30” is recommended between stove top and the bottom of range hood. 

 

It is recommended that the range hood be vented vertically through the roof with a minimum of a 6” or larger vent work.   

 

ALWAYS, when possible, reduce the number or transitions and turns. If a long duct run is required, increase duct size from 

6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer.    Reducing duct size will 
restrict/decrease airflow.   

 

The size of the vent should be uniform.     

 

Use no more than three 90° elbows.   

 

Make sure there is a minimum of 24” (61 cm) of straight vent between the elbows if more than one elbow is used.   

 

 

4. VENTING METHODS 

5. ELECTRICAL REQUIREMENTS 

6. TOOLS YOU WILL NEED 

Pencil or Marker 

 

Phillip Screwdriver 

Level 

Aluminum Tape 

Wall/Keyhole Saw 

Tape Measure 

Powered Screwdriver 

 

Hex bit extension 

 

 

CABINET 

JACK 

CAR JACK 

OPTIONAL 

(2) 2” x 4” x 24” (1) 24” x 36”/42” x ¾” plywood 

Note: about 6” wider than stove is ok 

 

 

Stud 

finder 

 

Содержание Deluxe DL09-U36

Страница 1: ...HESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY INSTALLATION GUIDE USER S MANUAL UNDER CABINET RANGE HOOD Pro X Series PX10 U30 36 42 48 PX11 U30 36 42 PX12 U30 36 42 Ultra Series UL10 U30 36 42 UL11 U30 36 42 UL13 U30 36 42 Deluxe Series DL09 U36 42 48 ...

Страница 2: ... this manual is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It is re...

Страница 3: ... aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended that the range...

Страница 4: ...L11 UL13 DL09 M B MANUAL BOOK 1 1 1 1 1 1 1 O T OIL TUNNEL 1 1 1 1 1 1 1 S 1 1 SCREW 2 2 2 2 2 2 4 S 2 1 SCREW 4 4 4 4 4 4 4 B F BAFLE FILTERS 3 3 3 3 3 3 3 36 42 4 48 R C REMOTE CONTROL 1 N A 1 N A N A N A N A 7 PARTS SUPPLIED 8 HOOD DIMENSIONS PX10 UL10 PX11 UL11 DL09 PX12 UL13 ...

Страница 5: ...have a 15amp 120V 60Hz single outlet on the left or right of the duct pipe usually is on of cabinet width Make sure duct pipe is ready to hook up to the range hood before beginning installation 8 diameter duct and roof or wall cap depending on where you will be venting your hood STEP 5 CREATE ACCESS Create or cut access opening for electrical wire and hood exhaust under the cabinet STEP 6 ATTACH T...

Страница 6: ...level 3 Slide forward into slot behind the front of hood 4 Slide the installed baffle filter to either left or right until it stops 5 Repeat step 1 to 4 to install the next ones make sure you slide to opposite direction from the previous installed filter To remove the baffle please reverse the process NOTE The middle filter has to be installed last where it should be taken out first when you want ...

Страница 7: ...tion 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working D Activating Smoke Detector Function ...

Страница 8: ...the same the next time it is turned on B ADJUSTING BLOWER SPEED Touch and hold down for increase Touch and hold down for decrease C TURNING OFF THE BLOWER Touch and hold down power sign 1 for 1 2 seconds D TO TURN THE LIGHT ON OFF Touch Light button 6 once to turn on the lights and once again to turn off the lights E ADJUSTING THE TIMER FUNCTION While the blower motor is not running touch and hold...

Страница 9: ...l power has been turned back ON Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs 2 The range hood vibrates when the blower is on The range hood might not have been secured properly to the cabinet or wall Check if the blower wheel is damaged 3 The blower or fan seems weak 12 SPECIFICATION 13 TROUBLESHOOTING A Make sure the range hood is unplugged or turn...

Страница 10: ...performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior su...

Страница 11: ...www XtremeAirUsa com PAGE 11 16 LIMITED WARRANTY ...

Отзывы: