IMPORTANT:  READ AND SAVE THESE INSTRUCTIONS 
 
                    FOR RESIDENTIAL & INDOOR USE ONLY 

 

 

INSTALLATION GUIDE & USER’S MANUAL 

 

 

  UNDER CABINET RANGE HOOD

 

  Pro-X Series: PX10-U30/36/42/48 
                  PX11-U30/36/42 
                  PX12- U30/36/42 
  Ultra Series: UL10- U30/36/42 

 

                UL11- U30/36/42 

     

 

          UL13- U30/36/42 

Deluxe Series: DL09-U36/42/48 

Содержание Deluxe DL09-U36

Страница 1: ...HESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY INSTALLATION GUIDE USER S MANUAL UNDER CABINET RANGE HOOD Pro X Series PX10 U30 36 42 48 PX11 U30 36 42 PX12 U30 36 42 Ultra Series UL10 U30 36 42 UL11 U30 36 42 UL13 U30 36 42 Deluxe Series DL09 U36 42 48 ...

Страница 2: ... this manual is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It is re...

Страница 3: ... aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended that the range...

Страница 4: ...L11 UL13 DL09 M B MANUAL BOOK 1 1 1 1 1 1 1 O T OIL TUNNEL 1 1 1 1 1 1 1 S 1 1 SCREW 2 2 2 2 2 2 4 S 2 1 SCREW 4 4 4 4 4 4 4 B F BAFLE FILTERS 3 3 3 3 3 3 3 36 42 4 48 R C REMOTE CONTROL 1 N A 1 N A N A N A N A 7 PARTS SUPPLIED 8 HOOD DIMENSIONS PX10 UL10 PX11 UL11 DL09 PX12 UL13 ...

Страница 5: ...have a 15amp 120V 60Hz single outlet on the left or right of the duct pipe usually is on of cabinet width Make sure duct pipe is ready to hook up to the range hood before beginning installation 8 diameter duct and roof or wall cap depending on where you will be venting your hood STEP 5 CREATE ACCESS Create or cut access opening for electrical wire and hood exhaust under the cabinet STEP 6 ATTACH T...

Страница 6: ...level 3 Slide forward into slot behind the front of hood 4 Slide the installed baffle filter to either left or right until it stops 5 Repeat step 1 to 4 to install the next ones make sure you slide to opposite direction from the previous installed filter To remove the baffle please reverse the process NOTE The middle filter has to be installed last where it should be taken out first when you want ...

Страница 7: ...tion 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working D Activating Smoke Detector Function ...

Страница 8: ...the same the next time it is turned on B ADJUSTING BLOWER SPEED Touch and hold down for increase Touch and hold down for decrease C TURNING OFF THE BLOWER Touch and hold down power sign 1 for 1 2 seconds D TO TURN THE LIGHT ON OFF Touch Light button 6 once to turn on the lights and once again to turn off the lights E ADJUSTING THE TIMER FUNCTION While the blower motor is not running touch and hold...

Страница 9: ...l power has been turned back ON Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs 2 The range hood vibrates when the blower is on The range hood might not have been secured properly to the cabinet or wall Check if the blower wheel is damaged 3 The blower or fan seems weak 12 SPECIFICATION 13 TROUBLESHOOTING A Make sure the range hood is unplugged or turn...

Страница 10: ...performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior su...

Страница 11: ...www XtremeAirUsa com PAGE 11 16 LIMITED WARRANTY ...