Before installation, inspect the unit and packaging to make sure that nothing inside has been damaged.
Placement & Storage
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Place the UPS away
from other units at least 7.8 in (20 cm) to avoid interference. DO NOT operate the UPS where the temperature and
humidity is outside the specified limits. (See Specifications for details).
Connect UPS to Utility and Charging
Before the initial use of the UPS, plug the UPS input cord into a wall outlet and turn the UPS on by depressing the
Power switch on the front of the UPS. For best results, the batteries in the UPS should be charged for at least 6
hours before use. The UPS charges its battery while it is connected to AC utility power and powered on.
Connecting the Loads
Plug the loads to be supported by the UPS into the output receptacles on the rear of the UPS. Simply turn the
power switch on the UPS on and the devices connected to the UPS will be protected by the UPS unit.
Connect Modem / Phone for Surge Protection
(S70 -1000, -1500, -2000 models only)
Connect a single modem/phone line into surge-protected “IN” outlet on the back of the UPS unit. Connect from
“OUT” outlet to the computer with phone line cable.
Connect Communication Cable
To allow for unattended UPS shutdown/start-up and status monitoring, connect one end of the communication
cable to the USB port and the other end to a USB port of a PC. With the monitoring software installed, you will be
able to schedule UPS shutdown/start-up and to monitor the UPS status through the PC.
Turn UPS ON / OFF
To turn the UPS unit on, press the Power switch on the front of the UPS. To turn the UPS unit off, press the Power
switch on the front of the unit again.
Cold Start Function
When the UPS is off and there is not input utility power available, it is still possible to cold start the UPS unit to
power loads. Follow the instructions for Turning UPS ON and be aware that you will see and hear the ON BATTERY
ALARM.
IMPORTANT SAFETY INSTRUCTIONS: (SAVE THESE INSTRUCTIONS)
CAUTION! (UPS having Internal Batteries):
Risk of electrical shock – Hazardous live parts inside this unit are ener-
gized from the battery supply even when the input AC power is disconnected.
CAUTION! (No User serviceable Parts):
Risk of electrical shock, do not remove cover. No user serviceable parts