manualshive.com logo in svg
background image

Xtreme Power Conversion Corporation

S70 User’s Manual

Page 3

Uninterruptible Power Supply

Package Contents

You should be receiving the following items inside the package:

•  UPS Unit

•  User Manual

•  Local Monitoring Software CD

•  USB cable

Product Introduction

Thank you for selecting this Uninterruptible Power Supply (UPS). It provides you with protection for connected 

equipment. Please read this manual before installing the S70 Series UPS models S70-500, S70-700, S70-1000, 

S70-1500, and S70-2000 as it provides important information that should be followed during installation and main-

tenance of the UPS and batteries, allowing you to correctly set up your system for the maximum safety and per-

formance. Included is information on customer support and service, if it is required. If you experience a problem 

with the UPS, please refer to the Troubleshooting section in this manual to correct the problem. If the problem is 

not corrected, please collect information so that the Technical Support personnel can more effectively assist you.

Product Overview

Many different kinds of sensitive electrical equipment can be protected by an Uninterruptible Power Supply (UPS) 

including computers, workstations, process control systems, telecommunications systems, sales terminals, other 

critical instrumentation, etc. The purpose of the UPS is to protect these systems from poor quality utility power, 

complete loss of power, or other associated problems.

Electrical interference exists in many forms, causing problems in AC power, from lightning, power company ac-

cidents and radio transmission motors, air conditioners, and vending machines. Protection of sensitive electrical 

equipment is vital to protect against power outages, low or high voltage conditions, slow voltage fluctuations, 

frequency variations, differential and common-mode noise, transients, etc.

To prevent power line problems from reaching critical systems causing damage to software, hardware, and equip-

ment malfunctions, the UPS maintains constant voltage, isolating critical load output and cleaning the utility AC 

power.

Line Interactive Technology

A line interactive technology UPS provides basic power protection and Automatic Voltage Regulation (AVR) to the 

load when AC input power is available. When AC input power is unavailable, the line-interactive UPS will switch to 

batteries to supply the load with power. In the event that the power failure lasts longer than the UPS backup time, 

the UPS will shut down avoiding battery damage. When the input AC voltage returns, the UPS will automatically 

return online to recharge the batteries.

•  AC input flows into and through the AVR to the load.

•  When AC input varies outside the acceptable specification, the AVR switches taps on the transformer to 

better regulate the output.

•  If AC input power fails, the inverter turns on an supplies power from the batteries to the load.

•  When AC input power returns, the UPS automatically begins supplying the load with power through the 

AVR circuit.

•  The charger circuit provides recharge for the batteries.

Содержание 500VA

Страница 1: ...S70 Line Interactive Tower UPS 500VA 700VA 1000VA 1500VA 2000VA Models User Installation Manual www xpcc com 2014 Xtreme Power Conversion Corporation All rights reserved Rev 8 13 14...

Страница 2: ...ly Table of Contents Package Contents 3 ProductIntroduction 3 ProductOverview 3 LineInteractiveTechnology 3 Installation Initial Startup 5 Troubleshooting 7 Specifications 8 Obtaining Service 9 Xtreme...

Страница 3: ...associated problems Electrical interference exists in many forms causing problems in AC power from lightning power company ac cidents and radio transmission motors air conditioners and vending machine...

Страница 4: ...Xtreme Power Conversion Corporation S70 User s Manual Page 4 Uninterruptible Power Supply...

Страница 5: ...unit Connect Modem Phone for Surge Protection S70 1000 1500 2000 models only Connect a single modem phone line into surge protected IN outlet on the back of the UPS unit Connect from OUT outlet to the...

Страница 6: ...can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with ins...

Страница 7: ...usly sounds when the AC input is normal The UPS is overloaded Remove some of the load from the output of the UPS When power fails backup time is shorter than expected The UPS is overloaded Remove some...

Страница 8: ...SICAL UPS dimensions W x D x H 3 9 x 11 3 x 5 6 in 5 7 x 13 8 x 6 3 in 5 7 x 15 6 x 8 1 in Shipping dimensions 5 5 x 13 1 x 8 7 in 7 5 x 17 4 x 10 in 9 1 x 19 3 x 11 3 in UPS weight 9 5 lbs 10 8 lbs 1...

Страница 9: ...ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorizati...

Страница 10: ...ipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an...

Страница 11: ...C Limited Warranty against certain losses caused by a Power Disturbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions provi...

Страница 12: ...Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except for dam...

Страница 13: ...payment to the Purchaser for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above XPC reserves the rig...

Отзывы: