background image

ИНСТРУКЦИЯ

Eaton 5P 850VA (9210-3359)

 

 

Summary of Contents for 5P 850VA

Page 1: ...Eaton 5P 850VA 9210 3359...

Page 2: ...manual Tower models 5P 650i 5P 850i 5P 1150i 5P 1550i 1U Rack models 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Copyright 2013 EATON All rights reserved Service and support Call your local service rep...

Page 3: ...ecial Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information RISK OF ELECTRIC SHOCK Observe the warning associated with the risk of electric...

Page 4: ...l installation of rack models 650i R 850i R 1150i R 13 3 4 Installation of rack models 650i R only 14 3 5 Installation of rack models 850i R 1150i R 1550i R 14 3 6 Communication ports 15 4 Operation 1...

Page 5: ...dboard Sacks and bags are made of polyethylene Packing materials are recyclable and bear the appropriate identification symbol 01 PET Materials Abbreviations Number in 01 the symbols PET Polyethylene...

Page 6: ......

Page 7: ...1150i 10 91 24 10 345 x 150 x 233 13 6 x 5 9 x 9 2 5P 1550i 15 95 35 20 445 x 150 x 233 17 5 x 5 9 x 9 2 Rack models D H W Description Weights kg lb Dimensions mm inch D x W x H 5P 650i R 8 6 19 00 36...

Page 8: ...OFF or RPO Remote Power Off control 5 Outlets for connection of critical equipment Primary group 6a Group 1 programmable outlets for connection of equipment 6b Group 2 programmable outlets for connect...

Page 9: ...ion card 4 Connector for ROO remote ON OFF or RPO Remote Power Off control 5 Outlets for connection equipment Primary group 6a Group 1 programmable outlets for connection of equipment 6b Group 2 progr...

Page 10: ...8 Escape Up Down Enter On Off button Rack models Alarm Up On Off Indicator red button Normal mode 100 10min 100 720 W 800VA Efficiency 98 On battery Indicator yellow Power On Indicator green Down Ente...

Page 11: ...until button is not pressed Normal mode The UPS is operating normally The UPS is powering and protecting the equipment In AVR mode No beep The UPS is operating normally but the utility voltage is out...

Page 12: ......

Page 13: ...settings The following table displays the options that can be changed by the user Description Available settings Default settings Local settings Language English Fran ais Deutsch Italiano Portugu s E...

Page 14: ...Enable If enabled UPS will shutdown after 5min of back up time if no load is detected on the output Disable Sleep mode Disable Enable If disabled LCD and communication will turn OFF immediately after...

Page 15: ...es for the protected equipment 5 RS232 communication cable 6 USB communication cable 7 Cable locking systems 1 x 4 outlets 650i R and 850i R models 1 x 6 outlets 1150i R and 1550i R models 8 1U Rack k...

Page 16: ...3 Installation 3 2 Installation of tower models ENGLISH 3 3 Wall installation of rack models 650i R 850i R 1150i R 1 2 2 1 620 00082 02 i en Page 13...

Page 17: ...ly Follow steps 1 to 3 for rack mounting 1 2 3 3 2 3 5 Installation of rack models 850i R 1150i R 1550i R Follow steps 1 to 4 for module mounting on the rails 1 1 2 3 2 3 4 4 The rails and necessary h...

Page 18: ......

Page 19: ...ation port on the UPS The UPS can now communicate with EATON power management software It is not necessary to shutdown the UPS before installing a communication card 1 Remove the slot cover 3 secured...

Page 20: ...in ON OFF Settings on page 11 To start the UPS on battery 1 Press the button on the UPS front panel until the UPS front panel display illuminates and shows a status of UPS starting The UPS cycles thro...

Page 21: ...tained by opening a contact connected between the appropriate pins of connector 4 on the rear panel of the UPS see figures below 4 Remote control connection and test 1 Check that the UPS is OFF and di...

Page 22: ...from the UPS The UPS continues to operate but may shutdown if the load increases The alarm resets when the condition becomes inactive End of battery life The end of the battery life is reached Contact...

Page 23: ...tray removal on tower models A Remove the front panel A B Disconnect the battery block by separating the two connectors B never pull on the wires C C Remove the plastic protection cover in front of t...

Page 24: ......

Page 25: ...ors never pull on the wires C D Remove the metal protection cover in front of the battery two screws D E Pull the plastic tab to remove the battery block and replace it E Mounting the new battery modu...

Page 26: ...ance free Standard Tower 1 x 12 V 9 Ah 2 x 12 V 7 Ah 2 x 12 V 9 Ah 3 x 12 V 9 Ah Rack 2 x 6 V 9 Ah 4 x 6 V 7 Ah 4 x 6 V 9 Ah 6 x 6 V 9 Ah Environment Operating temperature range 0 to 35 C 0 to 40 C St...

Page 27: ...Page 22 620 00082 02 i en...

Page 28: ......

Reviews: