12
4.2.3 If the heat-resistance cloth on the heater is damaged, please replace it immediately.
4.2.4 Change the oil of the vacuum pump for every 300 hours. If the packaged product is full
of juice, shorten the oil replacing cycle time. Also check the oil level from oil sight
glass every week. Oil capacity should be kept at least two-thirds of total amount. If the
oil is dirty, please replace it immediately.
4.2.5 The disposal of discarded material should be in accordance with the local
environmental regulations.
4.2.6 Detail drawing of the oil pump
1.
Air release hole
2.
Oil filling hole
3.
Oil sight glass
4.
Oil draining hole
Содержание CM1500A
Страница 5: ...3 ...
Страница 17: ...15 ...
Страница 19: ...17 ...
Страница 21: ...19 ...
Страница 23: ...21 ...
Страница 25: ...23 ...
Страница 27: ...25 ...
Страница 29: ...27 ...
Страница 31: ...29 ...
Страница 33: ...31 T1 PW K1 STANDARD CHECKED PROCESSED NAME DATE CIRCUUIT DIAGRAM 02 PAGE E D C B A E D C B A MC1 RE1 FU APR ...
Страница 34: ...32 E PAGE 03 CIRCUUIT DIAGRAM DATE NAME PROCESSED CHECKED STANDARD E A B C D A B C D ...
Страница 42: ...40 A B C D E A B C D E DATE NAME PROCESSED CHECKED STANDARD Vacuum system ...
Страница 43: ...41 A B C D E A B C D E PAGE DATE NAME PROCESSED CHECKED STANDARD C1 Gas ...