STATUS INDICATIONS

LED Status 

Message

Fixture Status

Description

Action/Solution

No LED activity

No power/off

The fixture is not connected to 
the mains or the power is off

Check power

Short green flash with 

long off interval

Ballast stand-by (on EXT)

Fixture is connected to the mains 
and to a controller. Output of 
ballast is off

No action required

Long green flash with 

brief off interval

Ballast on (on EXT)

Fixture is connected to the mains 
and to a controller. Output of 
ballast is on

No action required

Solid green on with no 

off interval

Ballast on (Manual dim)

Fixture is connected to the mains 
and set to manual output

No action required

Rapid yellow flash

Fixture is igniting the lamp

Fixture is trying to restart the 
lamp

When lamp does not start: Lamp may 
be too hot, defective or not properly 
connected (remote). Disconnect, 
check power cord and connections

ERROR OR WARNING INDICATIONS

One rapid red flash with 

long off interval

Too low voltage

Input voltage is too low

Ballast power drops to 50% 
automatically

If used it with 120V input power 
accidently, the ballast power will 
decrease to 50% of the set power 
automatically. Turn off the ballast and 
replace it with correct 240V input 
power. If the voltage is a bit lower 
than 240V, the LED will blink and 
the ballast keeps running with set 
wattage.

One rapid yellow flash 

with long off interval

Too low voltage occurred 
in past

Input voltage was too low in 
the past

Ballast power drops to 50% 
automatically

See above, reset

Two rapid red flashes 

with medium-long off 

interval

Too high voltage

Input voltage is too high

Ballast power drops to 50% 
automatically

Disconnect the ballast. Check input 
voltage, check wiring and connection, 
check neutral in 3 phase systems, 
then reconnect the ballast. LED on 
the ballast will blink but power will 
not change.

Two rapid yellow 

flashes with medium-

long off interval

Too high voltage occurred 
in past

Input voltage was too high in 
the past

Ballast power drops to 50% 
automatically

See above, reset

Three rapid red flashes 

with brief off interval

Too high temperature

Electronics temperature is too 
high (max. 115°C/239°F)

There is temperature sensor in the 
PCB of the ballast. If it senses the 
internal ballast temperature reaches 
1100C, the LED will start to blink. The 
ballast power will decrease to 50% 
of the set power automatically. Users 
should turn off the ballast or cool 
down the ballast.

Three rapid yellow 

flashes with brief off 

interval

Too high temperature 
occurred in past

Electronics temperature was 
too high in the past (max. 
115°C/239°F)

See above, reset

One rapid red flash with 

prolonged off interval

No signal from controller 
(on EXT)

Fixture is connected to the mains 
and set to EXT but there is no 
signal on the control input.

If a controller is connected, search 
for loose connections, defective 
contacts or short-circuits. Re-connect 
the controller to the ballast or verify 
whether the controller is out of order..

7

Содержание XTDEOKT1

Страница 1: ...USER MANUAL XTDEOKT1 COMPLETE LIGHTING SYSTEM OPEN SYSTEM ...

Страница 2: ...re when it is plugged in Allow it to cool down be fore handling Recommended mounting clearance for your fixture is 8 12 on all sides Do not mount directly to any surface Make sure to disconnect the power when changing the lamp XTRASUN DE SERIES BALLAST ELECTRICAL SPECIFICATIONS Model Watts Main Voltage Operating Voltage Range Max Input Power OutputPowerSettings Power Factor Ignitor Voltage THD CF ...

Страница 3: ...PARTS LIST WHAT S INTHE BOX PARTS LIST A Complete Open System B DE Lamp C Power Cord D RJ14 Cables x2 E RJ Splitter F Rear Hanging Eye Hook G Spare Hanging Eye Hook A B C D E F G 3 ...

Страница 4: ...C 4 The wire ends leads must be fully seated as shown PHOTOS D E before sliding each socket end closed 5 After sliding the socket ends closed be certain that there is no gap between the edge of the sliding section and the part it meets at the end of the slide path Once lamp is positioned correctly slide the lamp holder inward toward the center of the bulb to secure and lock the lamp in place as sh...

Страница 5: ...n Never pull the cord to unplug the reflector pull the plug only Avoid scratching the bulb subjecting it to undue pressure or getting it wet when it is hot these actions may cause the bulb to break TIPS 1 Make sure your unit is unplugged 2 Install rear hanging eye hook to threaded stud on top of the ballast Tighten with adjustable wrench see images below 3 Hang the fixture from a strong cord or ch...

Страница 6: ...ividual colored dots do represent individual flashes black dots represent time that the LED is unlit between flashes They also represent the relative time duration of signals each dot still represents one half second For example the Too high voltage signal is shown as two red dots followed by two black dots This indicates two red flashes of one half second each followed by one second of a dark unl...

Страница 7: ...w voltage occurred in past Input voltage was too low in the past Ballast power drops to 50 automatically See above reset Two rapid red flashes with medium long off interval Too high voltage Input voltage is too high Ballast power drops to 50 automatically Disconnect the ballast Check input voltage check wiring and connection check neutral in 3 phase systems then reconnect the ballast LED on the ba...

Страница 8: ...sequential indirect or incidental damages of any kind including lost revenues lost profits or other losses in connection with the product Some states do not allow limitation on how long an implied warranty lasts or the exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the XTDEOKT1 covered ...

Отзывы: