background image

1.  Open both lamp holders by sliding them outwards and away from the center of the fixture, as 

shown in PHOTO C.

Do not apply excessive force when installing lamp.

NOTE: 

The bulb must be oriented so that the high voltage wire end/lead (the end near the getter, 

which is the small square tab attached to the wire loop) is installed in the socket end closest to the 

ballast as seen in 

DIAGRAM A

.

2.  Also be sure that the bulb is oriented so that the burner filament (the long wire that runs 

along the full length of the arc tube) is positioned upward, facing the top inside surface of the 

reflector. 

3.  Ensure that the wire ends/leads are not bent or frayed, as this will prevent proper installation. 

Begin by installing the double-ended lamp within the lamp holders shown in PHOTOS A, B & C.

4.  The wire ends/leads must be fully seated as shown (PHOTOS D & E) before sliding each socket 

end closed.

5.  After sliding the socket ends closed, be certain that there is no gap between the edge of the 

sliding section and the part it meets at the end of the slide path. Once lamp is positioned 

correctly, slide the lamp holder inward toward the center of the bulb to secure and lock the 

lamp in place as shown in PHOTOS F & G.

PLEASE NOTE:

 Do not force the lamp holders closed. This could cause damage to both the lamp and 

lamp holders. Do not handle lamp with bare hands. Always wear surgical or cloth gloves whenever 

possible when handling lamp to minimize fingerprints and oils left on the lamp. If the lamp needs 

cleaning after installation, use a soft dry cotton cloth to wipe off fingerprints/skin oils.

PHOTO A

PHOTO C

PHOTO B

Anode 

(Closest to Ballast)

Getter 

(absorbs lamp impurities)

Burner Filament 

(always position up)

Cathode

Arc Tube

Quartz Outer Jacket

DIAGRAM A

LAMP INSTALLATION

4

Содержание XTDEOKT1

Страница 1: ...USER MANUAL XTDEOKT1 COMPLETE LIGHTING SYSTEM OPEN SYSTEM ...

Страница 2: ...re when it is plugged in Allow it to cool down be fore handling Recommended mounting clearance for your fixture is 8 12 on all sides Do not mount directly to any surface Make sure to disconnect the power when changing the lamp XTRASUN DE SERIES BALLAST ELECTRICAL SPECIFICATIONS Model Watts Main Voltage Operating Voltage Range Max Input Power OutputPowerSettings Power Factor Ignitor Voltage THD CF ...

Страница 3: ...PARTS LIST WHAT S INTHE BOX PARTS LIST A Complete Open System B DE Lamp C Power Cord D RJ14 Cables x2 E RJ Splitter F Rear Hanging Eye Hook G Spare Hanging Eye Hook A B C D E F G 3 ...

Страница 4: ...C 4 The wire ends leads must be fully seated as shown PHOTOS D E before sliding each socket end closed 5 After sliding the socket ends closed be certain that there is no gap between the edge of the sliding section and the part it meets at the end of the slide path Once lamp is positioned correctly slide the lamp holder inward toward the center of the bulb to secure and lock the lamp in place as sh...

Страница 5: ...n Never pull the cord to unplug the reflector pull the plug only Avoid scratching the bulb subjecting it to undue pressure or getting it wet when it is hot these actions may cause the bulb to break TIPS 1 Make sure your unit is unplugged 2 Install rear hanging eye hook to threaded stud on top of the ballast Tighten with adjustable wrench see images below 3 Hang the fixture from a strong cord or ch...

Страница 6: ...ividual colored dots do represent individual flashes black dots represent time that the LED is unlit between flashes They also represent the relative time duration of signals each dot still represents one half second For example the Too high voltage signal is shown as two red dots followed by two black dots This indicates two red flashes of one half second each followed by one second of a dark unl...

Страница 7: ...w voltage occurred in past Input voltage was too low in the past Ballast power drops to 50 automatically See above reset Two rapid red flashes with medium long off interval Too high voltage Input voltage is too high Ballast power drops to 50 automatically Disconnect the ballast Check input voltage check wiring and connection check neutral in 3 phase systems then reconnect the ballast LED on the ba...

Страница 8: ...sequential indirect or incidental damages of any kind including lost revenues lost profits or other losses in connection with the product Some states do not allow limitation on how long an implied warranty lasts or the exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the XTDEOKT1 covered ...