background image

Xtralis ICAM 

Xtralis ICAM Communications Guide

 

www.xtralis.com 

i

 

Intellectual Property and Copyright 

This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their 
respective owners. Your use of this document does not constitute or create a licence or any other right to use the name and/or 
trademark and/or label. 

This document is subject to copyright owned by Xtralis AG (“Xtralis”). You agree not to copy, communicate to the public, adapt, 
distribute, transfer, sell, modify or publish any contents of this document without the express prior written consent of Xtralis. 

Disclaimer 

The contents of this document is provided on an “as is” basis. No representation or warranty (either express or implied) is 
made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to 
change designs or specifications without obligation and without further notice. Except as otherwise provided, all warranties, 
express or implied, including without limitation any implied warranties of merchantability and fitness for a particular purpose are 
expressly excluded. 

General Warning 

This product must only be installed, configured and used strictly in accordance with the General Terms and Conditions, User 
Manual and product documents available from Xtralis. All proper health and safety precautions must be taken during the 
installation, commissioning and maintenance of the product. The system should not be connected to a power source until all 
the components have been installed. Proper safety precautions must be taken during tests and maintenance of the products 
when these are still connected to the power source. Failure to do so or tampering with the electronics inside the products can 
result in an electric shock causing injury or death and may cause equipment damage. Xtralis is not responsible and cannot be 
held accountable for any liability that may arise due to improper use of the equipment and/or failure to take proper precautions. 
Only persons trained through an Xtralis accredited training course can install, test and maintain the system. 

Liability 

You agree to install, configure and use the products strictly in accordance with the User Manual and product documents 
available from Xtralis. 

Xtralis is not liable to you or any other person for incidental, indirect, or consequential loss, expense or damages of any kind 
including without limitation, loss of business, loss of profits or loss of data arising out of your use of the products. Without 
limiting this general disclaimer the following specific warnings and disclaimers also apply: 

Fitness for Purpose 

You agree that you have been provided with a reasonable opportunity to appraise the products and have made your own 
independent assessment of the fitness or suitability of the products for your purpose. You acknowledge that you have not relied 
on any oral or written information, representation or advice given by or on behalf of Xtralis or its representatives. 

Total Liability 

To the fullest extent permitted by law that any limitation or exclusion cannot apply, the total liability of Xtralis in relation to the 
products is limited to: 

i.  in the case of services, the cost of having the services supplied again; or 

ii.  in the case of goods, the lowest cost of replacing the goods, acquiring equivalent goods or having the goods repaired. 

Indemnification 

You agree to fully indemnify and hold Xtralis harmless for any claim, cost, demand or damage (including legal costs on a full 
indemnity basis) incurred or which may be incurred arising from your use of the products. 

Miscellaneous 

If any provision outlined above is found to be invalid or unenforceable by a court of law, such invalidity or unenforceability will 
not affect the remainder which will continue in full force and effect. All rights not expressly granted are reserved. 

Содержание ICAM IFT Series

Страница 1: ...Xtralis ICAM Communications Guide October 31 2008 Document 16013_00 Part Number 29306 ...

Страница 2: ......

Страница 3: ...e equipment damage Xtralis is not responsible and cannot be held accountable for any liability that may arise due to improper use of the equipment and or failure to take proper precautions Only persons trained through an Xtralis accredited training course can install test and maintain the system Liability You agree to install configure and use the products strictly in accordance with the User Manu...

Страница 4: ...ent Convention Description Caution This icon is used to indicate that there is a danger to equipment The danger could be loss of data physical damage or permanent corruption of configuration details Warning This icon is used to indicate that there is a danger of electric shock This may lead to death or permanent injury Warning This icon is used to indicate that there is a danger of inhaling danger...

Страница 5: ...m 1 Table of Contents 1 Scope 2 2 Introduction to Xtralis ICAM Communications 3 3 RS232 Communications 4 4 TCP IP Connections 5 4 1 TCP IP Setup 5 5 RS485 Communications 7 5 1 IFT Single Remote Panel 7 5 2 IFT Mini Remote Display Unit 8 5 3 RS485 Network Setup 10 ...

Страница 6: ...cation protocols and then provides the reader with information on available communication devices The Xtralis ICAM Communications Product Guide is written for those people who are involved with the design specifications maintenance and purchase of Xtralis ICAM systems It is assumed that persons using this guide have knowledge of the local fire and electrical codes and standards Installers should h...

Страница 7: ...M Communications Xtralis ICAM Communications are based on three systems ICAM PC Software uses RS232 serial protocol allowing communications between a PC and the Xtralis ICAM family of products TCP IP protocol allowing communication between a PC and the Xtralis ICAM detector RS485 communications ...

Страница 8: ...nfigure any Icam Detector for setup prior to system commissioning and handover An RS232 9 pin Null Modem cable connects the PC to the serial port on the IFT product If an RS232 port is not available on the P C Laptop device a suitable USB Serial converter can be used The image below shows connectivity of the RS 232 USB converter cable to the PC Figure 3 1 ICAM IFT 15 detector connected to PC ...

Страница 9: ...nits as shown in Figure 4 1 The messageserver maintains a data base of connections to detector units and PC Software applications When a detector unit initially connects to the messageserver it informs it what data and commands it requires and what data and notifications it has to offer Similarly when a PC application connects to the messageserver it informs the messageserver what data it needs an...

Страница 10: ...CAM 6 www xtralis com 2 Connect all devices using a suitable Cat 5 cable to the router switch hub 3 Apply power to all units connected Assign static IP addresses to each device on the network 4 Ping each device to ensure good data communications ...

Страница 11: ...km away from the main system using a suitable high quality RS485 cable Xtralis recommends Belden 9841 9842 9841 Single twisted pair for comms only 9842 Double twisted pair 1 pair for comms 1 pair for 24V supply The RS485 cable is terminated at the IFT I O PCB and at the remote panel The diagram below details connection of RS 485 and 24 VDC at the IFT I O PCB i602 The RS485 cable must also be termi...

Страница 12: ...Press MAIN MENU twice to revert to normal display Once initialized the main IFT display and the remote will be operational If a button is pressed on the IFT display the remote panel will mimic Similarly if the remote panel buttons are pressed the IFT display panel will mimic The main IFT display can also be blanked off and fitted remotely in to the remote panel wall enclosure 5 2 IFT Mini Remote D...

Страница 13: ...ode The RDUs will then poll their corresponding IFT detector and show any alarm conditions faults and smoke levels The corresponding detector will detect if a user presses the Reset or Isolate buttons on an RDU Wiring Connections The above shows the wiring connections for the MqBridge Red Blue Power In to MqBridge 0 V 24 V Blue Yellow RS485 communications to Panels Black Red Power Out to Panels 0V...

Страница 14: ...tre between conductors 100 Ω to 120 Ω characteristic impedance Maximum signal attenuation over total length 16 dB at 0 25 MHz Overall screen to be connected at one end only The cable materials are not specified but in order to meet the low capacity specification polyethylene polyolefin polypropylene is used as the insulator with PVC flame retardant PVC as the overall sheath Other materials can be ...

Страница 15: ...w xtralis com 11 Bias Jumpers CN13 For the first and last detector on the RS485 network the jumpers should be 1 2 and 4 5 to bias the transmit receive lines For all other detectors all the jumpers should be removed Figure 5 2 Bias jumpers on detectors ...