8
XO I/O Interface USB Modules
8.1
About the XO I/O Interface USB Modules
Firmware version XO 4.0 and above supports the XO I/O Interface USB modules for extra inputs and outputs.
These modules contain sets of Main I/O and Extension I/O cards (Next Generation) that you can connect to your
XO device via USB.
XO I/O Interface USB module:
Rear view, single module:
The XO I/O Interface USB modules function just like internal MIO/EIO Next Generation cards, but with the
following restrictions:
l
There are no AUDIO OUT and AUDIO GND ouputs: if you want to use a VM22A audio switcher, you have to
connect it to the built-in MIO card instead. It is possible to use a VM22E switcher.
l
The RS-485 PTZ setting is 2-wire. You cannot change it to 4-wire.
l
You can add only one set of MIO/EIO cards to your device = a single XO I/O Interface USB module. You then
have two MIO cards and one EIO card in total. You cannot use the double module.
You have to map the MIO and EIO cards in the modules to the correct USB ports (ttyUx device nodes) using the
hardware configuration tool
. If not, the XO device will not discover the cards and you will not be able to use the
inputs/outputs.
For detailed information, see the
XO I/O Interface USB Module Technical Manual
(32688).
Note
Although it is technically possible to disable an existing, built-in MIO/EIO card in the hardware
configuration tool, and use an external module instead, Xtralis recommends to keep and use the built-
in cards. If you disable a built-in MIO card, you have to switch off the buzzer and watchdog features,
or the system will beep continuously. Switching off the buzzer and watchdog seriously reduces the
system's reliability and security.
8.2
Logging on to the Hardware Configuration Tool
You need to log on to the hardware configuration tool using the Technician user. For this, you need to:
1. Enable the Technician user using the XO client software.
2. Generate a special, temporary access code (PIN of the day) for the Technician user. The PIN limits the time
that the Technician user has access to the configuration tool.