![Xtrails ADPRO iFT Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/xtrails/adpro-ift/adpro-ift_hardware-installation-manual_890616034.webp)
iFT Series Hardware Installation Manual
ADPRO
34
27817_05
Normally open – DEOL
Short circuit = tamper
1K1 = alarm
3K3 = idle
Open circuit = tamper
Normally closed – DEOL
Short circuit = tamper
1K1 = idle
3K3 = alarm
Open circuit = tamper
(Default setting)
7.4
Connecting Inputs and Outputs
Depending on the type, the MIO card can be equipped with Dinkle (standard) or Phoenix spring insertion
connectors. For both types you need a 2 mm slotted screwdriver.
Warning!
Although the picture below shows only the connector, it is strongly recommended to connect the
wires with the connectors plugged into the card. Wiring a handheld connector may cause injuries.
Wiring to Dinkle and Phoenix connectors is identical, except that the position of tabs and holes is swapped. The
picture in the procedure below shows a Phoenix connector.
To connect inputs and outputs, proceed as follows:
1.
Push the slotted tab firmly inwards with the screwdriver.
2.
Insert the stripped wire (6–7 mm) into the corresponding round hole as deeply as possible.
3.
Release the tab and pull the wire to check if it is properly fitted.
Wire gauge:
Solid and stranded: 16–24 AWG
(diam. 1.3–0.5 mm)
7.5
Cable Strain Relief
After connecting all the wires, use a tie-wrap to attach the cables to the XO device’s chassis. Run the tie-wrap
through the slots in the chassis as shown below. The tie-wrap serves as a strain relief and makes sure that the
wiring stays in place when handling the XO device.