background image

XtendLan VC102SB – User’s Guide  

                              http://www.xtendlan.com 

 

- 10 - 

 

5 Hardware 

Description  

 

This section describes the important parts of the Modem. It features the front indicators and 
rear connectors.   

Front Indicators 

 

The following figure shows the front panel: 

 

At a quick glance of the front panel, it is easy to tell if the CPE Modem XL-VC102SB has 
power, if it has signal from its Ethernet RJ-45 port and if there is phone line signal on 
RJ-11port  

 
 

LED Description and Operation: 

 

LEDs 

 

Status 

 

Descriptions 

 

Ready  
(

Ready LED

)  

Steady Green   

It will light up (ON) to show that the product is 
power good, and system reset OK.   

Ethernet 
(

Ethernet LED

)  

Steady Green 

Flashing 

(LINK/ACT)  

Each RJ45 station port on the Ethernet is 
assigned an LED light for monitoring port “Good 
Linkage”. LED is normally OFF after the power 
on operation, but will light up steadily to show 
good linkage and flashing to show data 
transmission.  

VDSL  
(

VDSL LED

)  

Steady Green   

RJ11 station port on the VDSL is assigned an 
LED light for monitoring port “Good Linkage”. 
LED is normally OFF after the power on 
operation, but will light up steadily to show good 
linkage.  

 

Содержание XL-VC102SB

Страница 1: ...XL VC102SB VDSL CPE Slave bridge User s Guide ...

Страница 2: ...an com 2 Contents 1 VDSL POINT TO POINT SOLUTION 3 2 PRODUCT FEATURES SPECIFICATION 5 3 UNPACKING INFORMATION 7 4 INSTALLING THE MODEM 8 5 HARDWARE DESCRIPTION 10 6 CABLE REQUIREMENTS 12 7 TROUBLESHOOTING 13 8 COMPLIANCE AND SAFETY INFORMATION 16 ...

Страница 3: ...performance required to deliver high speed Internet access at much greater distances and drive services like IP telephony and audio video streaming With this technology a broad range of customers can benefit from lower operating costs and rapid deployment This solution provides a RS 232C console port for monitoring VDSL status and to configure speed This device is a CPE side solution and bridge be...

Страница 4: ... access the internet on the same wire simultaneously It even allows staying connected 24 hours on internet connections thus eliminating dial up prior to internet access The Modem is simple to install and use One RJ 45 Ethernet connects to a Router Ethernet Switch or to LAN card The RJ11 ports available to connect to any existing modular phone jack There are two RJ 11 jacks on the Modem to provide ...

Страница 5: ...indication Link for VDSL port Specifications Compliant with IEEE 802 3 802 3u Ethernet Standards Compliant with ETSI ITU ANSI VDSL standards 10 100M auto sensing RJ 45 Ethernet ports x 1 4 1 5 10 15 Mbps VDSL RJ 11 port x 1 POTS ISDN Splitter port RJ 11 x 1 Surge Protection Switch method store and forward Flow control Full duplex IEEE 802 3x Half duplex Backpressure Driver capable o 4 1Mbps 1 9km ...

Страница 6: ...XtendLan VC102SB User s Guide http www xtendlan com 6 Certifications FCC CE Mark class A EN60950 ...

Страница 7: ...checklist Package Contents VDSL CPE x 1 Four plastic feet x 4 AC To DC Power Adapter x 1 RJ 45 cable x 1 RJ 11 cable x 1 Please inform your dealer immediately for any missing items or damaged parts If possible retain the carton including the original packing materials Use them to repack the unit in case there is a need to return for repairing ...

Страница 8: ...or installation are available Connecting the Modem The Modem has one Ethernet port which support connection to Ethernet operation The devices attached to these ports must support auto negotiation or 10Base T OR 100Base TX unless they will always operate at half duplex Use any of the Ethernet ports to connect to devices such as NIC Switch bridge or router You can also connect to another compatible ...

Страница 9: ...ure the tab on the plug clicks into position to ensure that it is properly seated 4 Do not plug a RJ 11 phone jack connector into the Ethernet port RJ 45 port This may damage the Modem Instead use only twisted pair cables with RJ 45 connectors that conform to Ethernet standard Notes Be sure each twisted pair cable RJ 45 does not exceed 100 meters 333 feet RJ 11 port use 24 26 gauge phone wiring we...

Страница 10: ...ion and Operation LEDs Status Descriptions Ready Ready LED Steady Green It will light up ON to show that the product is power good and system reset OK Ethernet Ethernet LED Steady Green Flashing LINK ACT Each RJ45 station port on the Ethernet is assigned an LED light for monitoring port Good Linkage LED is normally OFF after the power on operation but will light up steadily to show good linkage an...

Страница 11: ...dem Rear Connectors Connectors Description Type Line For connecting to the VDSL Modem Using a RJ 11 cable RJ 11 Phone For connecting to the telephone or Fax ISDN modem RJ 11 Ethernet For connecting to a Ethernet equipped device RJ 45 Power On 1 Check the adapter is properly connected 2 Verify the power LED is steadily on ...

Страница 12: ...signal 3 RX Ethernet differential receive signal 4 NC Unused 5 NC Unused 6 RX Ethernet differential receive signal 7 NC Unused 8 NC Unused Standard telephone wire of any gauge or type flat twisted or quad is used to connect the Modem to the telephone network A telephone cable typically consists of three pairs of wires one of which is used for transmission The connector at the end of the telephone ...

Страница 13: ...ution 1 Power off and re power on the VDSL Modem 2 Verify that the switch and attached device are powered on 3 Be sure the cable is plugged into both the switch and corresponding device 4 Verify that the proper cable type is used and its length does not exceed specified limits 5 Check the Modem on the attached device and cable connections for possible defects 6 Replace the defective Modem or cable...

Страница 14: ...XtendLan VC102SB User s Guide http www xtendlan com 14 ...

Страница 15: ...SL Therefore if the Link signal is disrupted e g by unplugging the network cable and plugging it back in again or by resetting the power the port will try to reestablish communications with the attached device via auto negotiation If auto negotiation fails then communications are set to half duplex by default Based on this type of industry standard connection policy if you are using a full duplex ...

Страница 16: ...ifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment If this telephone equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as po...

Страница 17: ... required to correct the interference at his own expense CE Mark Warning This is a CE class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Warranty The original owner that the product delivered in this package will be free from defects in material and workmanship for one year parts after purchase There ...

Отзывы: