69
Sometimes, rebuild is called recover; these two have the same meaning. The following table is the
relationship between RAID levels and rebuild.
RAID 0
Disk striping. No protection of data. VG fails if any hard drive fails or
unplugs.
RAID 1
Disk mirroring over 2 disks. RAID 1 allows one hard drive fails or
unplugging. Need one new hard drive to insert to the system and rebuild
to be completed.
N-way mirror
Extension to RAID 1 level. It has N copies of the disk. N-way mirror allows
N-1 hard drives fails or unplugging.
RAID 3
Striping with parity on the dedicated disk. RAID 3 allows one hard drive
fail or unplugging.
RAID 5
Striping with interspersed parity over the member disks. RAID 5 allows
one hard drive fail or unplugging.
RAID 6
2-dimensional parity protection over the member disks. RAID 6 allows two
hard drives fails or unplugging. If it needs to rebuild two hard drives at the
same time, it will rebuild the first one, then the other by sequence.
RAID 0+1
Mirroring of the member RAID 0 volumes. RAID 0+1 allows two hard
drives fails or unplugging, but at the same array.
RAID 10
Striping over the member RAID 1 volumes. RAID 10 allows two hard
drives fails or unplugging, but at different arrays.
RAID 30
Striping over the member RAID 3 volumes. RAID 30 allows two hard
drives fails or unplugging, but at different arrays.
RAID 50
Striping over the member RAID 5 volumes. RAID 50 allows two hard
drives fails or unplugging, but at different arrays.
RAID 60
Striping over the member RAID 6 volumes. RAID 60 allows four hard
drives fails or unplugging, but each two at different arrays.
JBOD
The abbreviation of
“J
ust a
B
unch
O
f
D
isks
”
. No protection of data. VG
fails if any hard drive fails or unplugs.
Содержание xl-raid-2804issa
Страница 1: ...XL RAID 2804ISSA iSCSI SATA II SUBSYSTEM Installation and Configuration Manual Revision 1 0 ...
Страница 84: ...84 4 Click OK 5 Click Targets ...
Страница 93: ...93 Click Advanced Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK ...
Страница 95: ...95 ...
Страница 101: ...101 Log on Enable Enable multi path checkbox Then click Advanced ...
Страница 102: ...102 Select Target Portal to iSCSI data port 1 192 168 11 229 Then click OK Log on again ...
Страница 104: ...104 iSCSI device is connected Click Details Click Device tab then click Advanced ...
Страница 105: ...105 Click MPIO tab select Load Balance Policy to Round Robin Click Apply ...
Страница 108: ...108 After connected click Details then in the Session tab click Connections Choose Round Robin for Load Balance Policy ...
Страница 110: ...110 The MC S setting is done ...
Страница 112: ...112 Disable Immediate Data and enable Initial R2T Click OK ...
Страница 113: ...113 Click Save settings and click Yes on next page Click Refresh and find a new target with iSCSI name ...
Страница 115: ...115 Then run Computer Management in Windows Make sure the disk appears ...
Страница 119: ...119 block size 512B for 64bit OS setting block size 4K for 32bit OS setting Attach LUN for iSCSI controller Attach LUN ...