Coax MDU Master Bridge User’s Guide
This diagnosis runs the downstream test from XL-HCW128C toward EP.
Also the result of ‘
Rx Diagnose
’ of the same gears,
This diagnosis runs the upstream test from EP to XL-HCW128C.
The shown factors ‘
SNR
’, ‘
Lost Pkts
’, ‘
PE
’ and ‘
RX Power
’ are obtained during communication diagnosis
between the tested EP device and Master device.
SNR
: Normally
between
38dB~42dB.
Lost Pkts
: Denominator is the total number of transmitted packets in one test run. Numerator is the number of lost
packets in one test run.
PE
:
112Mbps/128Mbps/144Mbps (best connection carrier speed, in bits per second) for normal connection.
XL-HCW128C will adopt lower carrier speed automatically for connection path with high attenuation
(lower SNR).
Rx Power
: measured signal power
Administration
The settings include the Administrator account, the allowable Host with specified source IP, and the protocols like
HTTP/TELNET/ICMP/SNMP in XL-HCW128C management. Set up the criteria for management packets toward
XL-HCW128C. Irrelevant for data packets pass through XL-HCW128C toward EP.