23
2U Series
1
,
2
,
3
,
4
ALARM 1 to ALARM 4. The alarm becomes active in low voltage.
NO1 C1
,
NO2 C2
,
NO3 C3
,
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
Earth cable.
T+, T-, R+, R-
RS485 port
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120T
Ω between A/B cables if there are
too many PTZ decoders.
2U Series (16ch)
1
,
2
,
3
,
4,, 5, 6, 7,
8, 9, 10, 11, 12, 13,
14, 15, 16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
NO1 C1
,
NO2 C2
,
NO3 C3
,
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
CTRL 12V
Control power output. You need to close the device power to cancel
the alarm.
+12V
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
T+, T-, R+, R-
RS485 port
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120T
Ω between A/B cables if there are
too many PTZ decoders.