background image

-16-

SETUP INSTRUCTIONS

Switching Access Control:

UNLOCK Indicator:OFF
CALL Indicator:ON

Buzzer

Beep+, Beep

Show the master card of 

MASTER CARD ADD to ID 

card window in standby.

UNLOCK Indicator:ON
CALL Indicator:ON

Buzzer

Beep+, Beep

Show the master card of 

MASTER CARD DELETE 

to ID card window.

UNLOCK Indicator:OFF
CALL Indicator:OFF

Buzzer

Beep+

Show the master card of 

MASTER CARD DELETE

again to switch as a door 

station access control.

UNLOCK Indicator:OFF
CALL Indicator:OFF

Buzzer

Beep,Beep

Show the master card of 

MASTER CARD DELETE

again to switch to ACC

controlled.

The access can be controlled by door station or DPA-D2-ACC,so it’s available to switch the access 
function.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

If current access is controlled by door station, next access switching setting is controlled by DPA-D2-ACC.

Adding User Cards:

UNLOCK Indicator:OFF
CALL Indicator:ON

Buzzer

Beep+, Beep

Show the master card of 

MASTER CARD ADD to ID 

card window in standby.

UNLOCK Indicator:OFF
CALL Indicator:Blink one time

Buzzer

Beep+

Show user cards to be 

added in sequence. 

UNLOCK Indicator:OFF
CALL Indicator:OFF

Buzzer

Beep, Beep+

Show the master card of 

MASTER CARD ADD again 

to exit.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

To add user card, the access must be controlled by door station.

Содержание DPC-D268

Страница 1: ... this manual carefully to ensure safe and correct operation Keep this manual well for future reference RF CARD DPC D268E 12S DPC D268 8S ID DPC D268 8S 2 WIRE SYSTEM DPC D268 Fisheye door station with proximity access control ...

Страница 2: ...rd 9 Setting Prompt Voice 9 Setting Prompt Voice Volume 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Image Display Mode 13 RAINY_COVER Configure 14 Registering ID Card 15 Restore To Default 17 WIRING 18 Connecting Electric Lock 18 As The Villa System Door Stations 19 As The Apar...

Страница 3: ... unit and rain cover should be not less than 3mm Main unit 3mm AcDbMLeader ACDB_MLEADER_CLASS AcDbMLeader ACDB_MLEADER_CLASS AcDbMLeader ACDB_MLEADER_CLASS AcDbMLeader ACDB_MLEADER_CLASS Rainy cover Main unit 1 Drill holes in the wall to match the size of screw stoppers then attach the rainy cover to the wall 2 Connect the cable correctly and attach the main unit to the rainy cover The distance be...

Страница 4: ... Main Connect Port To connect the bus line and the electronic locks L1 L2 Connect to the bus line no polarity PL External lock power input connect to the power positive power S Lock power output S Lock power output connect to the power input of locks only when using the door station to power the locks if using the external power supply for the locks the S will not be connected 1 2 3 Lock Control J...

Страница 5: ...res the monitor with fisheye function to support The angle view is 1700 visitors in this angle view can be seen clearly and can be zoomed to see individuals up close via indoor monitor with fisheye function The door station is equipped with a terminal to connect external motion detector If the external motion detector is connected to the system following functions will be effec tive If detect some...

Страница 6: ...station address 0 3 0 2 Setting door station calling mode Standard Group calling mode Standard calling mode 3 Setting camera N P standard N P standard P standard 4 Setting prompt voice Max 9 voices Voice 1 5 Setting prompt voice volume 1 9 6 6 Setting the unlock mode 0 opened 1 closed 0 opened 7 Setting the unlock time 01 to 99 seconds 1 seconds 8 Setting the nameplate illumination mode On Off Aut...

Страница 7: ...dicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep Beep ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station SETUP INSTRUCTIONS If setting mode has not been exited you can change the address of door station by pressing KEY1 4 freely The LED_NAME indicator will always blink until exit out the setting ...

Страница 8: ...Call buttonE call the monitor with address 05 by default Call buttonF call the monitor with address 06 by default Call buttonG call the monitor with address 07 by default Call buttonH call the monitor with address 08 by default Call buttonA Call all monitors in group address from 00 15 one of the monitor should be set to 00 Call buttonB C D E F G H Call all monitors in group address from 16 31 one...

Страница 9: ...Indicator OFF CALL Indicator ON Buzzer Play the voice 1 Press KEY_3 button to set the prompt voice to Voice 1 UNLOCK Indicator OFF CALL Indicator ON Buzzer Play the voice 2 Press KEY_3 button again to set the prompt voice to Voice 2 Beep UNLOCK Indicator OFF CALL Indicator ON Buzzer Press KEY_3 button again and again to set the prompt voice to No voice Press KEY_3 SETUP INSTRUCTIONS If setting mod...

Страница 10: ...mode to Normally opened UNLOCK Indicator ON CALL Indicator OFF Buzzer Beep Beep Press KEY_1 button again to set the unlock mode to Normally closed Press KEY_1 If setting mode has not been exited you can change the unlock mode by pressing KEY1 circularly The LED_NAME indicator will blink all the time until exit out the setting mode If without any operation in 10 seconds it will exit out setting mod...

Страница 11: ...tion mode to Normally on UNLOCK Indicator ON CALL Indicator OFF Buzzer Beep Beep Press KEY_3 button again to set the nameplate illumina tion mode to Normally off UNLOCK Indicator ON CALL Indicator OFF Buzzer Beep Beep Beep Press KEY_3 button again and again to set the nameplate illumination mode to Auto Press KEY_3 When entering time delayed setting the buzzer sound one time every second The LED_N...

Страница 12: ...o Auto Press KEY_4 UNLOCK Indicator ON CALL Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON CALL Indicator ON Buzzer Beep Press KEY_1 button to set the ring back call tone ringing one time UNLOCK Indicator ON CALL Indicator ON Buzzer Beep Beep Press KEY_1 button again to set the ring back call tone ringing continuously UNLOCK Indicator ON CALL Indi...

Страница 13: ...When answering the call image switching reminder is not effective Zoom mode When answering the call the image will be displayed on full screen for 5 sec onds then switch to Zoom image to remind to enter talking status UNLOCK Indicator ON CALL Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON CALL Indicator ON Buzzer Beep Press KEY_2 button to set the...

Страница 14: ...seconds then switch to Full screen to remind to enter talking status If set to forbidden mode there is no image switching reminder at any image display mode Activated is default to change the setting please follow the steps RAINY_COVER Configure If can be set the rainy cover mode Mounting the rainy cover is default to change the setting please follow the steps UNLOCK Indicator ON CALL Indicator ON...

Страница 15: ...cards When registered new master cards the old master cards will be invalid automatically SETUP INSTRUCTIONS UNLOCK Indicator Blink two times CALL Indicator OFF Buzzer Beep Beep Show the first card to ID card window set the card of MASTER CARD ADD UNLOCK Indicator Blink three times CALL Indicator OFF Buzzer Beep Beep Beep Show the second card to ID card window set the card of MASTER CARD DELETE UN...

Страница 16: ...be controlled by door station or DPA D2 ACC so it s available to switch the access function If without any operation in 10 seconds it will exit out setting mode automatically If current access is controlled by door station next access switching setting is controlled by DPA D2 ACC Adding User Cards UNLOCK Indicator OFF CALL Indicator ON Buzzer Beep Beep Show the master card of MASTER CARD ADD to ID...

Страница 17: ...10 seconds it will exit out setting mode automatically To add user card the access must be controlled by door station If without any operation in 10 seconds it will exit out setting mode automatically To add user card the access must be controlled by door station At step3 the UNLOCK CALL indicator will blink all time until formatting is finished When formatting is finished UNLOCK CALL indicator wi...

Страница 18: ...Exit Button EB 5 The Unlock Mode must be set to 0 by default 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3 The jumper must be taken off before connecting 4 Setup the Unlock Mode according to different lock types Power on to unlock type Unlock Mode 0 by default Power off to unlock type Unlock Mode 1 EB LOCK Jumper ...

Страница 19: ...Page 8 for more details about the address setting of door stations As The Villa System Door Stations 100 240VAC DBC4A1 A B C D OFF ON Impedance switch BUS IM BUS DS PC6A AC ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S RF CARD RF CARD RF CARD RF CARD Code 0 DIP6 off Code 30 DIP6 off Code 31 DIP6 on ...

Страница 20: ...stem door stations The door station is also compatible with other monitors which are provided by our company WIRING RF CARD RF CARD RF CARD BUS IM BUS DS PC6A AC OUT DS BDU IN IN OUT DS BDU IN IN BUS IM BUS DS PC6A AC A B C D DBC4A1 NEXT DBC4A1 NEXT DBC4A1 BUS IM BUS DS PC6A AC A B C D DBC4A1 ...

Страница 21: ...lied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional APPENDIX Power supply DC 24V Power consumption Standby 1 2W Working 4 8W Camera lens Color CMOS 2 0 Mega pixel 1 2 7 fisheye camera 1700 wide angle Lock Power supply 12Vdc 250mA Internal Power Number of relay circuits 2 the s...

Страница 22: ... limited in the D2 system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40 Twisted cable 2x1mm2 80 120 60 A B PC6A RF CARD Basic IN OUT Wiring Mode ...

Страница 23: ... 23 B A C 2 2 DBC4A1 PC6A RF CARD Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Star Topology Wiring Mode With DBC4A1 ...

Страница 24: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved ...

Отзывы: