-15-
Registering ID Card
•
Up to 320 user cards can be registered by the door station.
•
Easy management with LED status and sound hints.
•
There are two master cards, one
MASTER CARD ADD
card
and one
MASTER CARD DELETE
card, When registered new
master cards, the old master cards are invalid automatically.
•
Card reading distance is less than 3cm.
•
The master cards are necessary when you add or delete user
cards. Please keep it well for future use.
•
EM card, 125kHz.
Authorizing master cards:
By default,there are two master cards marked
MASTER CARD ADD
and
MASTER CARD
DELETE
,but you should know that the master card can be authorized by users at any time.
That means any two user cards can be authorized to master cards,When registered new master
cards, the old master cards will be invalid automatically.
SETUP INSTRUCTIONS
UNLOCK Indicator:Blink two times
CALL Indicator:OFF
Buzzer
Beep,Beep
Show the first card to ID
card window, set the card
of
MASTER CARD ADD
.
UNLOCK Indicator:Blink three times
CALL Indicator:OFF
Buzzer
Beep,Beep,Beep
Show the second card to ID
card window, set the card of
MASTER CARD DELETE
.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer
Beep+, Beep
When power on in 10s,press
and hold on
KEY_SET
button
for 3s.
UNLOCK Indicator:Blink one time
CALL Indicator:OFF
Buzzer
Beep+
Press
KEY_2
button.
•
The
LED_NAME
indicator will blink twice per second until exit out the master card authorized mode.
•
If without any operation in 10 seconds, it will exit out setting mode automatically.
•
It will exit out setting mode automatically after showing these two cards,the UNLOCK&CALL indicator will be
turned off.