Input Ganging and Output Ganging
The method of linking inputs or outputs together during editing is achieved in the same way, so only crossover (output)
ganging will be explained here. Having selected
Crossover Ganging
Crossover Ganging
Crossover Ganging
Crossover Ganging
from the menu under the
Crossover
Crossover
Crossover
Crossover
Sub
Sub
Sub
Sub-
-
-
-Menu
Menu
Menu
Menu
, the current ganging set-up will be displayed. This will either be a preset selection as would be useful in a
standard crossover configuration – for example
<
<<
<-
-
-
-Crossover Ganging
Crossover Ganging
Crossover Ganging
Crossover Ganging
Ganging=1+3+5+7 2+4+6+8
Ganging=1+3+5+7 2+4+6+8
Ganging=1+3+5+7 2+4+6+8
Ganging=1+3+5+7 2+4+6+8
…would be a logical ganging arrangement if the crossover was set up as a 4 x 2 way – linking the control and adjustment of
all “Low” outputs together, and that of all “High” outputs together.
However, if the crossover has not been set up with a preset routing configuration, then it may be required to set up the
ganging to compliment this configuration. This is achieved using the
Free Assign
Free Assign
Free Assign
Free Assign
mode. This is selected from the
preset ganging choices
5
, which are:
Ganging=None
Ganging=None
Ganging=None
Ganging=None
[all outputs independent]
Ganging=Free Assign
Ganging=Free Assign
Ganging=Free Assign
Ganging=Free Assign
[choose ganging]
Ganging=1+2+3+4+5+6+7+8
Ganging=1+2+3+4+5+6+7+8
Ganging=1+2+3+4+5+6+7+8
Ganging=1+2+3+4+5+6+7+8
[1 x 8 way]
Ganging=1+5 2+6 3+7 4+8
Ganging=1+5 2+6 3+7 4+8
Ganging=1+5 2+6 3+7 4+8
Ganging=1+5 2+6 3+7 4+8
[4 x 2 way]
Ganging=1+3+5+7 2+4+6+8
Ganging=1+3+5+7 2+4+6+8
Ganging=1+3+5+7 2+4+6+8
Ganging=1+3+5+7 2+4+6+8
[2 x 4 way]
Selecting
Free Assign
Free Assign
Free Assign
Free Assign
and then pressing
ENTER
will begin the process of ganging outputs together using the
following simple rules:
All outputs are ganged to the lowest number – so to gang 3 & 5, 5 must be selected and then ganged to 3.
Outputs cannot share more than one ganging set – so for example output 3 cannot be ganged to 2 and 4 unless
they are ganged together as well. (Effectively 3 and 4 are ganged to 2 in this case)
With these rules in mind, selecting and setting up gangs is quite straightforward.
Press a
MUTE
key to choose the output to gang – its LED will begin to flash, and an
EDIT
key will illuminate to show
which output it is currently ganged with. To change this selection, just press another
EDIT
key, remembering that gangs
work from the highest to lowest number. So, to gang outputs 1 and 5, press
MUTE
5
then
EDIT
1
– the display will show
<
<<
<-
-
-
-Crossover Ganging
Crossover Ganging
Crossover Ganging
Crossover Ganging
Gang Output 5 with 1
Gang Output 5 with 1
Gang Output 5 with 1
Gang Output 5 with 1
Ganging is cleared by selecting
Ganging=None
Ganging=None
Ganging=None
Ganging=None
from the initial choices given above. The
Input Ganging
Input Ganging
Input Ganging
Input Ganging
procedure is identical to the crossover ganging, selectable under the
Input Sub
Input Sub
Input Sub
Input Sub-
-
-
-Menu
Menu
Menu
Menu
.
5 Ganging choices will be dependent on the
4 Series
4 Series
4 Series
4 Series
unit in question and how many outputs it has.
Содержание 4 Series
Страница 1: ...1 10...
Страница 2: ...Page 2 4 Series 4 Series 4 Series 4 Series Operator s Manual...
Страница 55: ...Operators Manual Page 55 2 x 2 Way 2 Aux 1 x 6 way...
Страница 57: ...Operators Manual Page 57 4 x 1 way...