31
6. With the trigger gun held open, siphon enough water out of the 5
gallon container until there is just enough water left to mix with the
antifreeze.
7. Point the trigger gun into the empty container. (Be certain to wear
safety attire for protection from splashing.)
8. Trigger the gun until the antifreeze begins to exit the trigger gun.
Release the trigger for 3 seconds, then trigger the gun for 3 seconds.
Continue cycling the trigger gun several times until all the antifreeze
mixture is siphoned from the container.
9. Stop the unit.
10. Detach the 3 foot hose from the unit and drain any excess antifreeze
back into the 5 gallon container.
FLOAT TANK MODELS:
1. Remove lid from float tank.
2. Start the unit and squeeze the trigger gun until the float tank is almost
empty.
3. Stop the unit.
4. Mix antifreeze and water in a container that can be used for pouring the
solution into the float tank.
5. Start the unit. Point the trigger gun into the empty container. Trigger
the gun until the antifreeze begins to exit the trigger gun. Continue
cycling the trigger gun several times until all the antifreeze mixture is
siphoned from the container.
6. Stop the unit.
e. Disconnect the hose and trigger gun from the unit and drain any
excess antifreeze back into the 5 gallon container.
f. Drain hose, trigger gun and dual lance assembly and store with the
unit in a safe non-freezing area.
g. Store antifreeze solution for next use or dispose of according to
state EPA laws.
3. OPTIONAL PROCEDURE:
a. Shut the unit and water supply off.
b. Relieve system pressure by pointing the trigger gun in a safe
direction and squeezing the trigger until water flow ceases to exit the
nozzle.
c. Disconnect and drain the hose, trigger gun and lance assembly.
d. Remove the coil drain plug from the heat exchanger inlet.
e. Start the unit and allow it to run until all the water exits the unit.
Once the water has stopped flowing from the unit, turn off.
maintenance
Содержание X-HW13008GEN
Страница 1: ...operation manual X HW13008GEN X HW33008GEN HOT WATER PRESSURE WASHER...
Страница 2: ...2 table of contents...
Страница 13: ...13 features 8 Operator s Manual 0MHSE00 GEN 032905 RZ Hse small frame features Features Small Frame...
Страница 40: ...40 If you need assistance with the assembly or operation of this Pressure Washer please call 1 866 770 1711...